{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"140AVI03000C","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"140AVI03000C","canonicalUrl":"https://aoctrl.com/schneider/140AVI03000C","factsUrl":"https://aoctrl.com/api/mcp/products/140AVI03000C","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Modicon Quantum 140AVI03000C analog input module, 8-channel differential, 16-bit resolution, 2.2 W, chassis mount, CE, UL 508.","salesMarkdown":"## Overview The 140AVI03000C is a Schneider Modicon Quantum automation platform analog input module, order code 140AVI03000C, providing 8 differential input channels with 16-bit resolution. It draws 2.2 W and mounts on a chassis in the Quantum rack, handling voltage and current signals across standard ranges. Each of the 8 differential inputs accepts ±10 V, ±5 V, 0–10 V, 0–5 V, 0–20 mA, or 20 mA signals, resolved to 16 bits. A single-pole low-pass filter at 847 Hz ±20 % conditions the signal; update time is 10 ms per module. Accuracy is -0.03 % of full scale, linearity error ±0.008 %. The module detects broken wire on 4–20 mA loops and overtacking on 1–5 V inputs. Absolute maximum input is 50 V DC or 25 mA without damage. Addressing requires 9 input words in the Quantum backplane. ## Applications This analog input module fits Modicon Quantum racks in process control, motor control centers, and drive systems where multiple analog sensors — pressure transmitters, temperature probes, flow meters — need isolated differential measurement. Typical installations include water treatment, material handling, and packaging lines. The 140AVI03000C carries UL 508, CSA C22.2 No 142, FM Class 1 Division 2, and cUL certifications, plus CE marking. It also lists California Proposition 65 compliance. No official end-of-life notice is recorded; the module remains a standard catalog item in the Modicon Quantum range.","metaTitle":"Schneider 140AVI03000C Modicon Quantum Analog Input Module, 8-Ch","metaDescription":"Schneider Modicon Quantum 140AVI03000C analog input module: 8 differential channels, 16-bit resolution, 2.2 W, chassis mount, UL 508, CE.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Unclassified"],"specifications":{"Marking":"CE","Category":"US1PC2118155","Standards":"UL 508 CSA C22.2 No 142","Fault type":"Broken wire 4...20 mA Overtacking scale 1...5 V","Input type":"Differential","Update time":"10 ms","Module format":"Standard","Type of filter":"Single pole low pass - 3 dB at 847 Hz +/- 20 %","Input impedance":"> 20 Ohm voltage 250 MOhm +/- 0.03 %","Linearity error":"+/- 0.008 %","lifecycle_stage":"eol_hot","Local signalling":"1 LED (green) for bus communication is present (Active) 1 LED (red) for external fault 8 LEDs (green) for channel is turned on 8 LEDs (red) for channel fault","Range of Product":"Modicon Quantum automation platform","Relative Humidity":"95 % without condensation","Operating altitude":"<= 16404.2 ft (5000 m)","Analogue input type":"Bipolar current 20 mA Bipolar voltage +/- 10 V Bipolar voltage +/- 5 V Unipolar current 0...20 mA Unipolar voltage 0...10 V Unipolar voltage 0...5 V","Protective treatment":"Conformal coating Humiseal 1A33","Analogue input number":"8","Nbr. of units in pkg.":"1","Absolute maximum input":"50 V DC 25 mA","Addressing requirement":"9 input words","Linear measuring range":"(input range) x 1.024 V (input range) x 1.024 mA","Power dissipation in W":"2.2 W","Absolute accuracy error":"+/- 0.03 % +/- 0.05 % of full scale maximum","Bus current requirement":"280 mA","Analogue input resolution":"16 bits +/- 10 V 16 bits +/- 5 V 16 bits 0...10 V 16 bits 0...20 mA 16 bits 0...5 V 16 bits 20 mA","Product or Component Type":"Analogue input module","Isolation between channels":"135 Vrms AC 200 V DC","Isolation between channels and bus":"500 Vrms AC 60 s 750 V DC","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Resistance to electromagnetic fields":"9.1 V/m (10 V/m) 80...1000 MHz IEC 801-3","Ambient Air Temperature for Operation":"32...140 °F (0...60 °C)","Resistance to electrostatic discharge":"4 kV contact IEC 801-2 8 kV on air IEC 801-2","Accuracy drift according to temperature":"+/- 0.0015 % of full scale/°C - 80 dB 60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,070.60 – $3,847.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4c99627f8a394b01587e6a19dea8e1dd.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/140AVI03000C/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/140AVI03000C","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/140AVI03000C when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}