{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"140DDM69000","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"140DDM69000","canonicalUrl":"https://aoctrl.com/schneider/140DDM69000","factsUrl":"https://aoctrl.com/api/mcp/products/140DDM69000","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Modicon Quantum 140DDM69000 mixed discrete I/O module, 4 inputs 125 VDC, 4 outputs 24-125 V DC 4 A, 8 I/O points.","salesMarkdown":"## Mixed I/O on Quantum The 140DDM69000 is a Modicon Quantum mixed discrete I/O module that is now end-of-life, meaning sourcing goes through surplus or broker channels for urgent BOM fills. It packs 4 sink inputs rated at 125 VDC and 4 source-or-sink solid-state outputs handling 24 to 125 VDC at up to 4 A per point. Response time is 0.5 or 1.5 ms depending on the noise filter setting. Protection is built in: each output group has a 5 A fuse, transient voltage suppression on outputs, and resistor-limited inputs. Channel-to-channel isolation is rated 1780 Vrms for 1 minute, and group-to-bus isolation is 2500 Vrms. Addressing takes one input word and one output word, and the module draws 350 mA from the bus. ## Sourcing an End-of-Life Module This module is end-of-life and no longer in production. Sourcing is via surplus or broker channels for new-in-box units from cancelled orders. ## Field Wiring and Commissioning Input wiring is sink logic. Outputs can be wired as source or sink. Watch the maximum leakage current: 1.2 mA at 150 VDC and load capacitance limits of 0.1 µF at 150 VDC or 0.6 µF at 24 VDC. The module operates up to 5000 m altitude and 95% relative humidity without condensation. Bus current budget is 350 mA; power dissipation is 0.4 W plus input and output loads.","metaTitle":"Schneider 140DDM69000 Quantum Mixed I/O, 125 VDC, 4 A","metaDescription":"End-of-life (eol_hot) 140DDM69000 mixed I/O module for Modicon Quantum. 4 inputs 125 VDC, 4 outputs 24-125 V 4 A. Sourced to order via surplus channel. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Marking":"CE","Category":"US1PC2118155","Standards":"UL 508 CSA C22.2 No 142 FM Class 1 Division 2","Response time":"0.5 or 1.5 ms depending on the filter at state 0 to state 1 0.5 or 1.5 ms depending on the filter at state 1 to state 0","Protection Type":"Internal output protection by 5 A fuse per group On output by transient voltage suppression On input by resistor limited","lifecycle_stage":"eol_hot","Fault indication":"Overcurrent on output","Local signalling":"1 LED (green) for bus communication is present (Active) 1 LED (red) for no voltage in output and input (F) 2 LEDs (red) for fault detected on the output point 4 LEDs (green) for output is turned on 4 LEDs (red) for fault detected on the input point","Range of Product":"Modicon Quantum automation platform","Power dissipation":"0.4 W + (1 x input point on) + (0.75 total output load current)","Relative Humidity":"95 % without condensation","Operating altitude":"<= 16404.2 ft (5000 m)","Discrete I/O number":"8","Discrete input logic":"Sink","Discrete output type":"Solid state, isolated","Input voltage limits":"156.2 V including ripple","Maximum load current":"<= 4 A per point","Maximum voltage drop":"<0.75 V 4 A","Discrete input number":"4 1 group of 8","Discrete output logic":"Source or sink","Nbr. of units in pkg.":"1","Output voltage limits":"19.2...156.2 V DC typical","Addressing requirement":"1 input word 1 output word","Associated fuse rating":"5 A","Discrete input voltage":"125 V DC","Discrete output number":"4 1 group of 4","Absolute maximum output":"30 A during 500 ms per point","Bus current requirement":"350 mA","Discrete output voltage":"24...125 V","Maximum leakage current":"1.2 mA 150 V DC","Maximum load capacitance":"0.1 µF 150 V DC 0.6 µF 24 V DC","Network frequency limits":"47...63 Hz","Product or Component Type":"Mixed discrete I/O module","Current state 0 guaranteed":"= 2 mA","Isolation between channels":"1780 Vrms for 1 minute","Voltage state 0 guaranteed":"0...36 V","Voltage state 1 guaranteed":"88...156.2 V","Isolation between group and bus":"2500 Vrms for 1 minute","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Resistance to electromagnetic fields":"9.1 V/m (10 V/m) 80...1000 MHz IEC 801-3","Ambient Air Temperature for Operation":"32...140 °F (0...60 °C)","Resistance to electrostatic discharge":"4 kV contact IEC 801-2 8 kV on air IEC 801-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$3,085.45 – $3,232.00","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/140DDM69000/alternatives.json"},"ai":{"faq":[{"question":"What are the key electrical ratings?","answer":"4 sink inputs at 125 VDC, 4 source/sink outputs at 24-125 VDC up to 4 A per point. Response time is 0.5 or 1.5 ms depending on the filter setting. Isolation: 1780 Vrms channel-to-channel, 2500 Vrms group-to-bus."},{"question":"How do I source this end-of-life module?","answer":"Via an RFQ. We source from surplus and broker channels; condition varies but typically new-in-box from cancelled orders. Submit a purchase order and we'll locate the best available units."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/140DDM69000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/140DDM69000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}