{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"140DDO36400C","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"140DDO36400C","canonicalUrl":"https://aoctrl.com/schneider/140DDO36400C","factsUrl":"https://aoctrl.com/api/mcp/products/140DDO36400C","rawCanonicalId":null},"summary":{"shortDescription":"Discrete Output Module","salesMarkdown":null,"metaTitle":"Schneider 140DDO36400C Discrete Output Module","metaDescription":"Schneider 140DDO36400C Modicon Quantum discrete output module, 96 outputs, 30 V, negative logic (sink), conformal coated, for industrial I/O.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Marking":"CE","Category":"US1PC2118155","Standards":"CSA C22.2 No 142 UL 508","Module format":"Standard","Response Time":"<= 0.1 ms at state 1 to state 0","Surge current":"2 A","Load inductance":"Inductance(H) = 0.5/((current(A))² x (switching frequency(Hz))) 0.5...4 Hz","lifecycle_stage":"eol_hot","Fault indication":"Fault sensing Loss of field power Fault reporting Fault point","Local signalling":"1 LED (green) for bus communication is present (Active) 1 LED (red) for external fault detected (F) 96 LEDs (green) for input status","Range of Product":"Modicon Quantum automation platform","Group of channels":"6 groups of 16","Power dissipation":"7 W","Relative Humidity":"95 % without condensation","Operating altitude":"<= 16404.2 ft (5000 m)","Maximum load current":"<= 3.2 A each group","Maximum voltage drop":"<0.4 V 0.5 A","Protective treatment":"Conformal coating Humiseal 1A33","Discrete output logic":"Negative logic (sink)","Nbr. of units in pkg.":"1","Output voltage limits":"19.2...30 V","Addressing requirement":"6 output words","Discrete output number":"96","Bus current requirement":"250 mA","Discrete output voltage":"24 V DC","Maximum leakage current":"1 mA 24 V","Short-circuit protection":"With","Product or Component Type":"Dc discrete output module","Output overload protection":"With","Isolation between channels and bus":"500 Vrms DC for 1 minute","Ambient Air Temperature for Storage":"-40...185 °F (-40...85 °C)","Resistance to electromagnetic fields":"9.1 V/m (10 V/m) 80...2000 MHz IEC 801-3","Ambient Air Temperature for Operation":"32...140 °F (0...60 °C)","Resistance to electrostatic discharge":"4 kV contact IEC 801-2 8 kV on air IEC 801-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e58ba51128c8b56b3d5cf0d53f5b841c.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/140DDO36400C/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/140DDO36400C","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/140DDO36400C when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}