{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"16751","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"16751","canonicalUrl":"https://aoctrl.com/schneider/16751","factsUrl":"https://aoctrl.com/api/mcp/products/16751","rawCanonicalId":null},"summary":{"shortDescription":"residual current circuit breaker ID - 4 poles - 25 A - class B 300 mA","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"72 mm","Colour":"Grey","Height":"86 mm","Standards":"IEC 61008 EN 61008 VDE 0664","9 Mm Pitches":"8","Network type":"AC","Product name":"Acti9 RCCB-ID","Tropicalisation":"2","lifecycle_stage":"unknown","Connection pitch":"18 mm between phases","Neutral position":"Left","Device short name":"RCCB-ID","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3 N.m","[In] rated current":"25 A","Electrical durability":"2000 cycles","Mechanical durability":"5000 cycles","Wire stripping length":"11 mm","Connections - terminals":"Tunnel type terminals2 cable(s) 1.5...16 mm² flexible Tunnel type terminals2 cable(s) 1.5...16 mm² rigid Tunnel type terminals1 cable(s) 1.5...50 mm² rigid Tunnel type terminals1 cable(s) 1.5...35 mm² flexible Tunnel type terminals1 cable(s) 1.5...35 mm² flexible with ferrule Tunnel type terminals2 cable(s) 1.5...16 mm² flexible with ferrule","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Product or component type":"Residual current circuit breaker (RCCB)","[Ui] rated insulation voltage":"440 V AC 50 Hz conforming to IEC 61008-1","Earth-leakage protection class":"Type B","[Ue] rated operational voltage":"230/400 V","Rated breaking and making capacity":"Im = 500 A conforming to IEC 61008","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-25...40 °C","[Uimp] rated impulse withstand voltage":"4 kV conforming to IEC 61008-1","Rated conditional short-circuit current":"Inc 10 kA 25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/16751/residual-current-circuit-breaker-id-4-poles-25-a-class-b-300-ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/16751/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/16751","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/16751 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}