{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"18687","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"18687","canonicalUrl":"https://aoctrl.com/schneider/18687","factsUrl":"https://aoctrl.com/api/mcp/products/18687","rawCanonicalId":null},"summary":{"shortDescription":"RCCB with re-closer - RED - 2 poles - 25 A - class A - 30 mA","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"79.5 mm","Reset":"Fault reset earth leakage","Width":"71 mm","Height":"115 mm","Standards":"EN 61008 IEC 61008","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 REDs","Mounting mode":"Fixed","Surge current":"250 A","Test function":"Manual at > 100 V","Operating mode":"Reclosing time: < 90 s Max nb of consecutive restart: 3 Min interval between 2 closings: 180 s Stopping restart cycle if insulation fault present Insulation fault presence monitoring","Product weight":"0.36 kg","Earthing system":"TN-S TT","Protection type":"Recloser","Tropicalisation":"2","lifecycle_stage":"unknown","Local signalling":"2 LEDs Residual current device : ON/OFF indication Recloser : ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Neutral position":"Left","Pollution degree":"2","Range Of Product":"Acti9","Device short name":"REDs","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"Power circuit: 2 N.m Signaling: 0.4 N.m","[In] rated current":"25 A","Mechanical durability":"1000 cycles open-close","Wire stripping length":"Power circuit: 12 mm Signaling: 9 mm","Connections - terminals":"Guard tunnel terminal 35 mm² rigid Guard tunnel terminal 35 mm² flexible Guard tunnel terminal 35 mm² flexible with ferrule","IP degree of protection":"IP20","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Product or component type":"Residual current circuit breaker (RCCB)","Signalling output current":"0.6 mA min 100 mA max, cos phi =1","Minimum leakage resistance":"16 kOhm at operating 8 kOhm at non-operating","Signalling circuit voltage":"AC: 5...230 V DC: 5...230 V","Signal contacts composition":"1NO or 1NC or intermittent 1 Hz","Auxiliary connection terminal":"Tunnel type terminal in 2.5 mm² flexible Tunnel type terminal in 2.5 mm² rigid Tunnel type terminal in 2.5 mm² flexible with ferrule","Electromagnetic compatibility":"8/20 µs wave immunity, 250 A","[Ui] rated insulation voltage":"500 V","Earth-leakage protection class":"Type A","[Ue] rated operational voltage":"230 V AC 50 Hz phase to neutral","Ambient air temperature for storage":"-20...60 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"4 kV","Rated conditional short-circuit current":"Inc: 6 kA - associated with DPN, 40 A Inc: 10 kA - associated with DPNN, 40 A Inc: 10 kA - associated with iC60N, 25 A Inc: 10 kA - associated with iC60H, 25 A Inc: 10 kA - associated with iC60L, 25 A Inc: 10 kA - associated with NG125, 25 A Inc: 10 kA - associated with gG fuse, 25 A","[Im] rated making and breaking capacity":"Idm 630 A 230 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/18687/rccb-with-recloser-red-2-poles-25-a-class-a-30-ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/18687/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/18687","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/18687 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}