{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1FT2208-4AF10-0RB0-Z P90+Q01","brand":"Siemens","brandSlug":"siemens","productSlug":"1FT2208-4AF10-0RB0-Z-P90Q01","canonicalUrl":"https://aoctrl.com/siemens/1FT2208-4AF10-0RB0-Z-P90Q01","factsUrl":"https://aoctrl.com/api/mcp/products/1FT2208-4AF10-0RB0-Z%20P90%2BQ01","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMOTICS S-1FT2 CT synchronous servo motor, 22 Nm M0, 3.7 kW PN at 3000 r/min, holding brake, resolver 2p, Pt1000, M17/M23 connectors, bulk pack 14.","salesMarkdown":"## What this motor delivers on the line The 1FT2208-4AF10-0RB0-Z P90+Q01 is a SIMOTICS S-1FT2 CT synchronous servo with a static torque M0 of 22 Nm and a rated power PN of 3.7 kW at nN=3000 r/min — sizing it for mid-range axis duties such as packaging, converting, and machine-tool feed drives where the 22 Nm stall window covers the peak load step without an oversized gearbox. It ships with an integrated holding brake, resolver 2p feedback, and a Pt1000 winding temperature sensor, all brought out through an M17 signal connector and an M23 power connector for a clean panel-side wiring path. The Z-coded option string flags two build choices that matter to procurement: P90 specifies bulk packaging at 14 units per pack rather than the individual carton, and Q01 is the named configuration suffix carried against the same 1FT2208-4AF10-0RB0 base. Both options are ordered together with the base code, not retrofitted. ## Lifecycle, class, and the orderable posture Siemens lists the as current and the product status as Active, so this code is still being booked through the standard Siemens ordering channel with no last-time-buy notice attached. The Group Code is R220 and the Product Group is X033, placing it inside the Siemens motion-control ordering structure. The Product class is the contract-built C designation: the unit is produced to order, cannot be reused or re-utilised, and is not returnable against credit. That governs how it should be handled on the receiving dock — once it lands against a specific BOM position, the credit pathway is closed and any mismatch is resolved through an engineering deviation, not an RMA. ## Compliance documentation on file RoHS substance-restriction compliance is declared since 11-02-21, and the REACH Art. 33 duty-to-inform line is carried as part of the product record — Siemens publishes the Reach Information document against this family. Export-control classification is AL: N with ECCN: N_CNDU, which means the part is not subject to a national-export or dual-use licence for the standard industrial destination. ## How it is specified and quoted Because the product class is made-to-order, the right sourcing motion is to lock the order code into the BOM, confirm the Z-option pair (P90 bulk pack and Q01) at RFQ, and let Siemens build against that confirmed string.","metaTitle":"Siemens 1FT2208-4AF10-0RB0-Z P90+Q01 Servo Motor","metaDescription":"Siemens SIMOTICS S-1FT2 CT servo motor, M0=22 Nm, PN=3.7 kW at 3000 r/min, holding brake, resolver 2p, Pt1000.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Servo Motors"],"specifications":{"title":"1FT2208-4AF10-0RB0-Z P90+Q01","Group Code":"R220","description":"SIMOTICS S-1FT2 CT synchronous motor M0=22 Nm; PN=3.7 kW at nN=3000 r/min; with holding brake; resolver 2p and Pt1000 with signal connector M17; power connector M23; P90: bulk packaging 14 units;","Product Group":"X033","Product class":"C: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.","Quantity Unit":"1 Piece","Product Family":"Ordering Data Overview","lifecycle_stage":"current","Packaging Quantity":"1","Export Control Regulations":"AL : N / ECCN : N_CNDU","Compliance with the substance restrictions according to RoHS directive":"Since: 11-02-21","REACH Art. 33 Duty to inform according to the current list of candidates":"Reach Information"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"{'url': 'https://mall.industry.siemens.com/mall/Document/GetDocumentBasedOnCode?code=aHR0cHM6Ly9tYWxsLmluZHVzdHJ5LnNpZW1lbnMuY29tL3NwaWNlL2RvY3VzZXJ2aWNlL2RvY3VzZXJ2aWNlP2NvbmZpZ2lkPTE0JmRvY3UubWxmYj0xRlQyMjA4LTRBRjEwLTBSQjAtWiUyMFA5MCUyQlEwMSZkb2N1LmluaXR0eXBlPU1MRkImZG9jdS5nZW5lcmF0aW9udHlwZT1WSUVXJmRvY3Uudmlld2lkPVBERiZyZWdpb249QUUmbGFuZ3VhZ2U9ZW4mZG9jdS5sYW5ndWFnZS5sb2NhbGUxPWVuJmRvY3UubGFuZ3VhZ2UubG9jYWxlMj1lbg==', 'path_name': 'bc35a5a7c7234315096faf88300b206f.pdf', 'path_url': 'https://s3.lax.sharktech.net/viassion/datasheets/sieportal_siemens/bc35a5a7c7234315096faf88300b206f.pdf', 'status': 1}","sourceUrl":"https://sieportal.siemens.com/en-ae/products-services/detail/1FT2208-4AF10-0RB0-ZP90Q01?tree=CatalogTree"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 1FT2208-4AF10-0RB0-Z P90+Q01?","answer":"RoHS substance-restriction compliance is declared since 11-02-21, and the REACH Art. 33 duty-to-inform line is carried on the record with a Reach Information document published against the family."},{"question":"What is the closest functional second-source for the 1FT2208-4AF10-0RB0-Z P90+Q01 — 6SL3210-5BE31-8CV0?","answer":"No cross-reference is on file. The Siemens SINAMICS V20 basic converter 6SL3210-5BE31-8CV0 is a different product class (a basic converter drive, not a synchronous servo motor) and does not match the 1FT2208-4AF10-0RB0-Z mechanically or electrically — it would not drop in as a drop-in replacement."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/1FT2208-4AF10-0RB0-Z-P90Q01","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/1FT2208-4AF10-0RB0-Z-P90Q01 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T21:34:47.348Z","lastPublished":"2026-07-22T21:34:47.348Z","indexable":true}}