{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SAM580000R1004","brand":"ABB","brandSlug":"abb","productSlug":"1SAM580000R1004","canonicalUrl":"https://aoctrl.com/abb/1SAM580000R1004","factsUrl":"https://aoctrl.com/api/mcp/products/1SAM580000R1004","rawCanonicalId":null},"summary":{"shortDescription":"ABB MS132 manual motor protector, rotary handle, 3-pole, order code 1SAM580000R1004, thermal-magnetic, setting range 22 to 32 A, AC-3 15 kW at 400 V, IEC/EN 60947-4-1, UL 508.","salesMarkdown":"The ABB 1SAM580000R1004 is a 3-pole manual motor protector with a rotary handle, set on the bench between 22 and 32 A by the panel builder before it leaves the shop. At 400 V three-phase it carries AC-3 motors up to 15 kW, with a rated operational current of 32 A and a conventional free-air thermal current of 32 A on the main circuit, which is the figure that actually decides what motor feeder it protects in service. ## UL/CSA picture for North American cabinets On the UL/CSA side the device is listed at 32 A with a maximum operating voltage of 600 V AC on the main circuit, and a 600 V AC general-use rating of 32 A — the cleanest figure for a control-builder doing a UL 508A panel. For three-phase motor loads the horsepower tables give 10 Hp at 200, 208 and 220 to 240 V AC, stepping to 25 Hp between 440 and 480 V AC and continuing through 550 to 600 V AC, which is what the wireman uses to size the feeder rather than the amperage. ## Thermal budget and endurance on a cyclic load Per-pole dissipation runs 3.2 to 6.7 W at the rated operating conditions, so when several protectors are grouped in a row the cabinet ventilation has to clear that local loss on top of the contactor stack next to it. Mechanical durability is 50000 cycles and electrical durability is 25000 cycles, which means on a high-cycling process the protective element — not the handle — will be the first thing to plan a service interval around. ## Mounting, wiring and the wireman's bench work The unit snaps onto a TH35-15 rail per IEC 60715 and is allowed in mounting positions 1 through 6, which removes the usual 'this side up only' fight during retrofits into a crowded back panel. Main-circuit terminations take 2.5 to 50 mm² stranded with a ferrule on the IEC side and 10-2/0 AWG stranded or 10-1/0 AWG on the UL/CSA side, tightened to 4 to 6 N·m (35 to 53 in·lb). The drive uses a 4 mm hex and the strip length is 17 mm on the main circuit. ## What the field tech sees during a fault The rotary handle carries ON / OFF / TRIP indication, so a tripped protector is readable without a laptop or an auxiliary — that is the first thing the night-shift tech checks before pulling covers. Mechanical shock rating is 25g for an 11 ms pulse per IEC 60068-2-27, which covers placement near a stamper or a press without a separate shock-mount bracket. ## Compliance trail for the declaration pack RoHS status is documented as Following EU Directive 2011/65/EU under RoHS information reference 1SAD938506-0050, and the environmental information reference is 1SAA918004-2401, which is what feeds the tech file when the QA reviewer asks for the materials declaration. The instruction manual referenced with the device is 1SAM507001R1001, which is the document the wireman quotes on the test sheet rather than a generic ABB leaflet.","metaTitle":"ABB 1SAM580000R1004 MS132 Motor Protector, 22-32 A","metaDescription":"ABB 1SAM580000R1004 MS132 manual motor protector, rotary handle, 3-pole, setting range 22 to 32 A, AC-3 15 kW at 400 V, IEC/EN 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"title":"MS497-32","Standards":"IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 508, CSA 22.2 No. 14","Power Loss":"at Rated Operating Conditions per Pole 3.2 ... 6.7 W","RoHS Status":"Following EU Directive 2011/65/EU","description":"MS497-32","Actuator Type":"Rotary Handle","Setting Range":"22 ... 32 A","Number of Poles":"3","Shipping Weight":"3.5 Kg","lifecycle_stage":"current","Pollution Degree":"3","RoHS Information":"1SAD938506-0050","Mounting Position":"Position 1 to 6","Tightening Torque":"Main Circuit 4 ... 6 N·m","Estimated Lead Time":"4-6 Weeks","Rated Frequency (f)":"Main Circuit 50 Hz","Ampere Rating UL/CSA":"32 A","Degree of Protection":"Housing IP20","Mounting on DIN Rail":"TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715","Electrical Durability":"25000 cycle","Mechanical Durability":"50000 cycle","Wire Stripping Length":"Main Circuit 17 mm","Horsepower Rating UL/CSA":"(200 V AC) Three Phase 10 Hp,(208 V AC) Three Phase 10 Hp,(220 ... 240 V AC) Three Phase 10 Hp,(440 ... 480 V AC) Three Phase 25 Hp,(550 ... 600 V AC)","Instructions and Manuals":"1SAM507001R1001","Recommended Screw Driver":"Hexagon 4","Tightening Torque UL/CSA":"Main Circuit 35 ... 53 in·lb","Environmental Information":"1SAA918004-2401","General Use Rating UL/CSA":"(600 V AC) 32 A","Rated Operational Voltage":"Main Circuit 690 V AC","Contact Position Indication":"ON / OFF / TRIP","Rated Insulation Voltage (Ui)":"690 V","Rated Operational Current (Ie)":"32 A","Connecting Capacity Main Circuit":"Flexible with Ferrule 1x 2.5 ... 50 mm²","Maximum Operating Voltage UL/CSA":"Main Circuit 600 V AC","Rated Operational Power AC-3 (Pe)":"(400 V) Three Phase 15 kW","Rated Operational Current AC-3 (Ie)":"32 A","Ambient Air Temperature Compensation":"Yes","Environmental Ambient Air Temperature":"Operation -20 ... +70 °C","Maximum Operating Altitude Permissible":"2000 m","Rated Impulse Withstand Voltage (Uimp)":"Main Circuit 6 kV","Connecting Capacity Main Circuit UL/CSA":"Flexible 1x 10-2/0 AWG Flexible 1/2x 10-1/0 AWG Stranded 1x 10-2/0 AWG Stranded 1/2x 10-1/0 AWG","Resistance to Shock acc. to IEC 60068-2-27":"11 ms Pulse 25g","Conventional Free-air Thermal Current (Ith)":"Main Circuit 32 A","Rated Service Short-Circuit Breaking Capacity (Ics)":"(230 V AC) 100 kA,(400 V AC) 50 kA,(440 V AC) 50 kA,(500 V AC) 11 kA,(690 V AC) 6 kA","Rated Ultimate Short-Circuit Breaking Capacity (Icu)":"(230 V AC) 100 kA, (400 V AC) 100 kA, (440 V AC) 100 kA, (500 V AC) 22 kA, (690 V AC) 12 kA","Rated Instantaneous Short-Circuit Current Setting (Ii)":"416 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$382.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/79f359ce72313ecb02465743ee9ee677.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What are the listed standards on this ABB MS132?","answer":"The 1SAM580000R1004 is declared to IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, UL 508 and CSA 22.2 No. 14, which covers both IEC and North American cabinet declarations on a single device."},{"question":"What is the listed power loss per pole on 1SAM580000R1004?","answer":"Per-pole power loss is 3.2 to 6.7 W at rated operating conditions, which is the figure to add into the cabinet thermal calc when several protectors group on the same rail section."},{"question":"What motor load does 1SAM580000R1004 actually protect?","answer":"On the IEC side it carries AC-3 motors up to 15 kW at 400 V three-phase at 32 A, and on the UL/CSA side 10 Hp at 200 to 240 V AC and 25 Hp at 440 to 480 V AC three-phase, all within a setting range of 22 to 32 A on the rotary dial."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SAM580000R1004","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SAM580000R1004 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}