{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SDA068104R1","brand":"ABB","brandSlug":"abb","productSlug":"1SDA068104R1","canonicalUrl":"https://aoctrl.com/abb/1SDA068104R1","factsUrl":"https://aoctrl.com/api/mcp/products/1SDA068104R1","rawCanonicalId":null},"summary":{"shortDescription":"ABB XT4N 250 TMA 200-2000 4p F F InN=50% distribution circuit breaker, In 200 A, Iu 250 A, 690 V, 4 poles.","salesMarkdown":"## 1SDA068104R1 — XT4N 250 TMA 200 A, 4-Pole That's the ABB XT4N 250 TMA 200-2000 4p F F InN=50% — a distribution circuit breaker with a fixed continuous current rating of 200 A (In) on a 250 A frame (Iu). The TMA trip unit is thermal-magnetic, adjustable? The type suffix InN=50% means the continuous current setting is pegged at 50% of the trip unit's nominal range — so no field adjustment up; it's fixed at that point. This is a current-production part, quoted to order with a 2-4 week lead.","metaTitle":"1SDA068104R1 ABB XT4 Distrib Circuit Breaker, In 200 A, 4p","metaDescription":"ABB XT4N 250 TMA 200-2000 4p distribution circuit breaker, In=200 A, Iu=250 A, 690 V, 50/60 Hz. Active production, 2-4 week lead time. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"In":"200","Iu":"250","Size":"XT4","Type":"XT4N 250 TMA 200-2000 4p F F InN=50%","Weight":"3 Kg","Trip units":"TMA","Product No.":"1SDA068104R1","Manufacturer":"ABB","Product Type":"Distribution Circuit Breakers","Number of Poles":"4 poles","Shipping Weight":"4 Kg","lifecycle_stage":"current","Dimensions (LxWxH)":"8.25cm x 14cm x 16cm","Rated Current (In)":"200 A","Rated Voltage (Ur)":"690 V","Estimated Lead Time":"2 - 4 weeks.","Rated Frequency (f)":"50 / 60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$590.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1f19a4dbb7fdfeae321a8f57eef2f49f.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/1SDA068104R1/alternatives.json"},"ai":{"faq":[{"question":"What is the rated current (In) and frame rating (Iu) of 1SDA068104R1?","answer":"The rated continuous current In is 200 A; the frame rating Iu is 250 A."},{"question":"Will 1SDA068104R1 drop into a panel specified for 1SDA068105R1?","answer":"Physically yes — same frame XT4, same dimensions, same footprint and mounting. Electrically the In differs (200 A vs 225 A), so the overcurrent protection setting changes. If the panel design accommodates a 200 A trip, it will fit without rewiring; verify coordination with the existing loads."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SDA068104R1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SDA068104R1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}