{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SDA068118R1","brand":"ABB","brandSlug":"abb","productSlug":"1SDA068118R1","canonicalUrl":"https://aoctrl.com/abb/1SDA068118R1","factsUrl":"https://aoctrl.com/api/mcp/products/1SDA068118R1","rawCanonicalId":null},"summary":{"shortDescription":"ABB XT4N 160 MA 100 MCCB, 3-pole, In 100 A, Iu 160 A, magnetic-only trip unit, 50/60 Hz, 690 V.","salesMarkdown":"## Motor protection breaker with magnetic-only trip The ABB 1SDA068118R1 is an XT4N frame MCCB with a magnetic-only (MA) trip unit, rated In=100 A continuous current on a Iu=160 A frame. This means the breaker provides short-circuit and magnetic protection only — there is no thermal overload element, so it relies on an upstream or external overload relay for motor running protection. The type code XT4N 160 MA 100 Im=500...1000 3p F F confirms the adjustable instantaneous trip range: 500 to 1000 A (5–10× In), which is the setting range for coordinating with motor inrush. Rated voltage is 690 V AC, covering 400 V and 480 V systems with headroom for 600 V class. The 3-pole configuration is standard for three-phase motor circuits. Frequency rating is 50/60 Hz, suitable for global installations. ## Sizing and coordination for motor branch circuits The 100 A rated current matches motor FLA up to about 100 A, but the magnetic-only trip means the breaker does not carry the overload function — pair it with a separate thermal overload relay or motor protection relay upstream. The adjustable instantaneous trip (Im=500–1000 A) lets you set the magnetic pickup above motor starting current to avoid nuisance trips on inrush, while still clearing a bolted fault. Frame size XT4N supports the 160 A continuous rating of the frame itself, so the breaker can be re-fitted with a higher-rated trip unit later if the motor load changes, without swapping the entire breaker. Dimensions are 8.25 cm wide × 10.5 cm deep × 16 cm high, fitting standard panel layouts for MCCB up to 100 A class.","metaTitle":"ABB 1SDA068118R1 XT4N MCCB, 100 A, Motor Protection","metaDescription":"ABB 1SDA068118R1 XT4N 160 MA 100 MCCB, 3-pole, 100 A rated current, magnetic-only trip unit for motor protection. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Size":"XT4","Poles":"3 poles","Weight":"2.1 Kg","Current":"100 A","Voltage":"690 V","Frequency":"50/60 Hz","Product Type":"XT4N 160 MA 100 Im=500...1000 3p F F","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$433.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c009c66ee366e243fc14a3d4cbb20540.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/1SDA068118R1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SDA068118R1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SDA068118R1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}