{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA895008R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA895008R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA895008R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA895008R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB PST85 series, softstarter, 1SFA895008R7000, 85 A in-line / 147 A inside-delta, 45 kW / 75 kW at 400 V, 400-690 V AC main circuit, 100-250 V AC control supply, built-in electronic overload, 0-120 s ramp time, FieldBusPlug communication.","salesMarkdown":"## PST85 Softstarter — 85 A In-Line, 75 kW Inside-Delta The ABB PST85 softstarter (1SFA895008R7000) is rated 85 A in-line connection and 147 A inside-delta, delivering 45 kW in-line or 75 kW at 400 V when wired inside-delta. The main circuit accepts 400-690 V AC, and the control supply runs on 100-250 V AC. Built-in electronic overload protection eliminates the need for a separate overload relay — the current limit function adjusts from 1.5 to 7x Ie, and the ramp time is configurable from 0 to 120 seconds. The initial voltage during start can be set between 30 and 70%. Communication is via the standard FieldBusPlug, and the unit includes run, fault, by-pass, and overload signal relays. The control circuit uses 24 V DC operation, and the tightening torque for control terminals is 0.5 N·m. ## Integration Notes Main circuit terminals are bars with an 8.5 mm hole diameter; the control circuit accepts rigid 1 x 2.5 mm² wire. The supply circuit connects with rigid 1 x 2.5 mm² as well. Ambient operating temperature range is 0 to +50 °C, and the degree of protection for main terminals is IP00 per IEC 60529 and IEC 60947-1. The unit includes a switch for inside-delta connection, which is how you get the higher 147 A / 75 kW rating. Starting capacity is 3x Ie for 15 seconds. Service factor is 115%.","metaTitle":"ABB PST85 1SFA895008R7000 Softstarter, 85 A In-Line, 75 kW D","metaDescription":"ABB PST85 softstarter 1SFA895008R7000: 85 A in-line / 147 A inside-delta, 45 kW / 75 kW at 400 V, 400-690 V AC main circuit, built-in electronic overload, 0-120 s ramp. Current lif","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Soft Starters"],"specifications":{"Ramp Time":"0 ... 120 second [unit of time]","Communication":"FiledBusPlug(Standard)","Terminal Type":"Main Circuit: Bars","Analog Outputs":"0...10 volts","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PST85","Tightening Torque":"Control Circuit 0.5 N·m","Fault Signal Relay":"Yes","Overload Protection":"Build-in electronic overload protection","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00","Overload Signal Relay":"Yes","Current Limit Function":"1.5 ... 7xIe","Ambient Air Temperature":"Operation 0 ... +50 °C","Rated Operational Voltage":"Main Circuit 400 ... 690 V AC","Service Factor Percentage":"115 %","Object Classification Code":"Q","Initial Voltage During Start":"30 ... 70 %","Signal Indication Fault (LED)":"Red","Integrated Electronic Overload":"Yes","Step Down Voltage Special Ramp":"100 ... 30 %","Connecting Capacity Main Circuit":"Hole Diameter 8.5 mm","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 250 V AC","Connecting Capacity Supply Circuit":"Rigid 1 x 2.5","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"DC Operation 24 V","Signal Indication Protection (LED)":"Yellow","Switch for Inside Delta Connection":"Yes","Connecting Capacity Control Circuit":"Rigid 1 x 2.5 mm²","Material Compliance/RoHS Information":"No declaration needed","Popular Downloads/Instructions and Manuals":"1SFC132003M0201","Starting Capacity at Maximum Rated Current Ie":"3xIe for 15s","Rated Operational Power - In-Line Connection (Pe)":"(400 V) 45 kW","Rated Operational Power - Inside Delta Connection":"at 400 V 75 kW","Popular Downloads/Data Sheet, Technical Information":"1SFC132005C0201","Rated Operational Current - In-Line Connection (Ie)":"85 A","Rated Operational Current - Inside Delta Connection":"147 A","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa895008r7000","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA895008R7000/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this PST85 softstarter?","answer":"85 A in-line / 147 A inside-delta, 45 kW / 75 kW at 400 V, main circuit 400-690 V AC, control supply 100-250 V AC, ramp time 0-120 s, built-in electronic overload."},{"question":"Where can I buy 1SFA895008R7000 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote."},{"question":"What communication interface does this softstarter use?","answer":"It uses the standard FieldBusPlug communication interface."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA895008R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA895008R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}