{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA895012R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA895012R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA895012R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA895012R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB PST210 series softstarter, order code 1SFA895012R7000, 210 A in-line rated operational current, 110 kW at 400 V, 100-250 V AC control supply.","salesMarkdown":"## What this PST210 softstarter does on your motor circuit The ABB PST210 1SFA895012R7000 is a softstarter for three-phase induction motors, rated 210 A in-line connection and 110 kW at 400 V. That 210 A figure is the continuous current the main terminals carry in a standard line configuration — sized for a motor drawing that full-load current, not a service-entrance rating. The inside-delta connection bumps it to 360 A and 184 kW at 400 V, which is the more common wiring for larger motors because it shifts the softstarter's thyristors out of the main power path once the bypass relay closes. Main circuit voltage range is 400 to 690 V AC, so it covers 400 V and 690 V industrial networks without a separate voltage tap. Control supply is 100-250 V AC — make sure your control transformer is sized for that range, not a fixed 120 V tap. The current limit function is adjustable from 1.5 to 7 times the motor rated current (Ie), and the ramp time spans 0 to 120 seconds. That ramp is the time the softstarter takes to bring the motor from standstill to full speed — set it long enough to avoid a hard start on a conveyor or pump, but short enough that the motor doesn't sit in current-limit too long. Main circuit terminals are bars with a 10.2 mm hole — expect to land lugged cable, not bare wire. Control circuit terminals accept 1 x 2.5 mm² rigid and need 0.5 N·m of torque. The supply circuit (the control power feed) also takes 1 x 2.5 mm² rigid. Degree of protection on the main terminals is IP00 per IEC 60529 and IEC 60947-1, so this lives inside a panel — no washdown exposure on the power lugs. Communication is via a FieldBusPlug (standard), meaning it accepts the ABB fieldbus adapter module that plugs into the front. No onboard Ethernet or PROFIBUS — the plug is the interface point. Analog output is 0-10 V, useful for feeding a speed reference or a panel meter showing motor current. Four signal relays are built in: run, fault, bypass, and overload. That covers the typical status feedbacks a PLC needs — run permissive, fault reset, bypass confirmation that the contactor has closed, and a dedicated overload trip signal. LEDs on the front show fault (red) and protection (yellow) status.","metaTitle":"ABB PST210 Softstarter 1SFA895012R7000, 210 A, 110 kW","metaDescription":"ABB PST210 softstarter 1SFA895012R7000. 210 A in-line, 110 kW at 400 V. Built-in electronic overload. Current production. Available to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Soft Starters"],"specifications":{"Ramp Time":"0 ... 120 second [unit of time]","Communication":"FiledBusPlug(Standard)","Terminal Type":"Main Circuit: Bars","Analog Outputs":"0...10 volts","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PST210","Tightening Torque":"Control Circuit 0.5 N·m","Fault Signal Relay":"Yes","Overload Protection":"Build-in electronic overload protection","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00","Overload Signal Relay":"Yes","Current Limit Function":"1.5 ... 7xIe","Ambient Air Temperature":"Operation 0 ... +50 °C","Rated Operational Voltage":"Main Circuit 400 ... 690 V AC","Service Factor Percentage":"115 %","Object Classification Code":"Q","Initial Voltage During Start":"30 ... 70 %","Signal Indication Fault (LED)":"Red","Integrated Electronic Overload":"Yes","Step Down Voltage Special Ramp":"100 ... 30 %","Connecting Capacity Main Circuit":"Hole Diameter 10.2 mm","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 250 V AC","Connecting Capacity Supply Circuit":"Rigid 1 x 2.5","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"DC Operation 24 V","Signal Indication Protection (LED)":"Yellow","Switch for Inside Delta Connection":"Yes","Connecting Capacity Control Circuit":"Rigid 1 x 2.5 mm²","Material Compliance/RoHS Information":"No declaration needed","Popular Downloads/Instructions and Manuals":"1SFC132003M0201","Starting Capacity at Maximum Rated Current Ie":"3xIe for 15s","Rated Operational Power - In-Line Connection (Pe)":"(400 V) 110 kW","Rated Operational Power - Inside Delta Connection":"at 400 V 184 kW","Popular Downloads/Data Sheet, Technical Information":"1SFC132005C0201","Rated Operational Current - In-Line Connection (Ie)":"210 A","Rated Operational Current - Inside Delta Connection":"360 A","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa895012r7000","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA895012R7000/alternatives.json"},"ai":{"faq":[{"question":"What is the ramp time on this PST210 softstarter?","answer":"The ramp time is adjustable from 0 to 120 seconds. That's the time the softstarter takes to accelerate the motor from stop to full speed."},{"question":"What communication interface does 1SFA895012R7000 use?","answer":"It uses a standard FieldBusPlug, which accepts an ABB fieldbus adapter module. There is no onboard Ethernet or serial port — the plug is the connection point."},{"question":"Where can I buy 1SFA895012R7000 and what is the lead time?","answer":"We source this part to order against an RFQ. Availability and current pricing are confirmed at quote time through our independent distribution channels."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA895012R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA895012R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}