{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA895013R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA895013R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA895013R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA895013R7000","rawCanonicalId":null},"summary":{"shortDescription":"PST250-690-70 Softstarter - 250 A - Main Circuit 400... 690 V AC","salesMarkdown":null,"metaTitle":"1SFA895013R7000 - ABB","metaDescription":"PST250-690-70 Softstarter - 250 A - Main Circuit 400... 690 V AC","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Soft Starters"],"specifications":{"Ramp Time":"0 ... 120 second [unit of time]","Communication":"FiledBusPlug(Standard)","Terminal Type":"Main Circuit: Bars","Analog Outputs":"0...10 volts","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PST250","Tightening Torque":"Control Circuit 0.5 N·m","Fault Signal Relay":"Yes","Overload Protection":"Build-in electronic overload protection","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00","Overload Signal Relay":"Yes","Current Limit Function":"1.5 ... 7xIe","Ambient Air Temperature":"Operation 0 ... +50 °C","Rated Operational Voltage":"Main Circuit 400 ... 690 V AC","Service Factor Percentage":"115 %","Object Classification Code":"Q","Initial Voltage During Start":"30 ... 70 %","Signal Indication Fault (LED)":"Red","Integrated Electronic Overload":"Yes","Step Down Voltage Special Ramp":"100 ... 30 %","Connecting Capacity Main Circuit":"Hole Diameter 10.2 mm","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 250 V AC","Connecting Capacity Supply Circuit":"Rigid 1 x 2.5","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"DC Operation 24 V","Signal Indication Protection (LED)":"Yellow","Switch for Inside Delta Connection":"Yes","Connecting Capacity Control Circuit":"Rigid 1 x 2.5 mm²","Material Compliance/RoHS Information":"No declaration needed","Popular Downloads/Instructions and Manuals":"1SFC132003M0201","Starting Capacity at Maximum Rated Current Ie":"3xIe for 15s","Rated Operational Power - In-Line Connection (Pe)":"(400 V) 132 kW","Rated Operational Power - Inside Delta Connection":"at 400 V 220 kW","Popular Downloads/Data Sheet, Technical Information":"1SFC132005C0201","Rated Operational Current - In-Line Connection (Ie)":"250 A","Rated Operational Current - Inside Delta Connection":"430 A","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa895013r7000","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA895013R7000/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA895013R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA895013R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}