{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896103R1100","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896103R1100","canonicalUrl":"https://aoctrl.com/abb/1SFA896103R1100","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896103R1100","rawCanonicalId":null},"summary":{"shortDescription":"ABB PSR3 series soft starter, order code 1SFA896103R1100, voltage ramp function, 208–600 V AC operational voltage, 24 V AC/DC control supply, screw terminals.","salesMarkdown":"The ABB 1SFA896103R1100 is a PSR3-series soft starter with a voltage-ramp starting method — it gradually increases motor terminal voltage during start, reducing inrush current and mechanical stress on the driven load. Ramp time is adjustable from 0 to 20 seconds, letting you tune the acceleration profile to match pump, fan, or conveyor applications. Rated for 208 … 600 V AC three-phase supply, with a 24 V AC/DC control circuit — standard for panel integration where a 24 VDC PLC output drives the start command. The initial voltage during start is adjustable between 40 % and 70 % of line voltage; the step-down ramp then finishes from 100 % down to 60 %. This two-stage profile lets you handle high-friction starts (higher initial kick) or gentle fluid coupling (lower kick). No built-in electronic overload — ABB recommends the MS116 manual motor starter (0.63 … 4.00 A range) for that function. If your BOM already uses MS116 breakers, this keeps the panel consistent. A run signal relay is present (green LED indication), but there is no fault signal relay, no bypass signal relay, and no overload signal relay — so if you need separate fault or bypass feedback to the PLC, plan for external auxiliary contacts. Screw terminals on main and control circuits, tightening torque 1 N·m (8.9 in·lb for UL/CSA). Main circuit accepts 0.75 … 2.5 mm² rigid wire; control circuit accepts 1 x 0.75 … 2.5 mm².","metaTitle":"ABB 1SFA896103R1100 PSR3-600-11 Soft Starter, 208-600 V AC","metaDescription":"ABB PSR3-600-11 soft starter (1SFA896103R1100) with voltage ramp, 0-20 s ramp time, 24 V AC/DC control. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"0 ... 20 second [unit of time]","Communication":"FiledBusPlug(Optional)","Terminal Type":"Screw Terminals","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSR3","Tightening Torque":"Control Circuit 1 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS116 0.63 ... 4.00","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"No","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"40 ... 70 %","Popular Downloads/EPLAN Data":"9AAC129232_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"100 ... 60 %","Connecting Capacity Main Circuit":"Rigid 1/2 x 0.75 ... 2.5 mm²","Popular Downloads/Wiring Diagram":"1SFC132030M0001","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"24 V AC/DC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1/2 x 0.75 ... 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Connecting Capacity Control Circuit":"1 x 0.75 ... 2.5 mm²","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 0.5 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 8.9 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132076M9901","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 0.75 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"3.9 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa896103r1100","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896103R1100/alternatives.json"},"ai":{"faq":[{"question":"What is the recommended overload relay for 1SFA896103R1100?","answer":"ABB recommends the MS116 manual motor starter in the 0.63 … 4.00 A range for overload protection."},{"question":"Does the ABB PSR3-600-11 have a built-in bypass contactor?","answer":"No — there is no bypass signal relay on this unit, and the soft starter uses voltage-ramp control without an internal bypass contactor."},{"question":"Where can I buy or get a price for ABB 1SFA896103R1100 PSR3-600-11 soft starter?","answer":"This part is sourced to order against your RFQ. Availability and pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896103R1100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896103R1100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}