{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896105R1100","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896105R1100","canonicalUrl":"https://aoctrl.com/abb/1SFA896105R1100","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896105R1100","rawCanonicalId":null},"summary":{"shortDescription":"ABB, PSR9 series softstarter, order code 1SFA896105R1100, rated 208–600 V AC with 0–20 s voltage ramp and 24 V AC/DC control supply.","salesMarkdown":"## PSR9 in the panel The ABB 1SFA896105R1100 is a PSR9-class soft starter that ramps the motor up with a voltage ramp over 0…20 s, sized for 208…600 V AC at 50/60 Hz on three-phase mains. It is built for a 4xIe for 6s starting duty — the figure that decides whether a given motor fits — so the motor's locked-rotor current and load inertia need to come in under that envelope. Initial voltage during start is adjustable from 40…70 % of line, with a step-down special ramp of 100…60 % available for the deceleration side. That trims the mechanical shock on the coupling without adding a separate braking device. ## Control-side wiring and what it does not do The control supply is 24 V AC/DC on the Uc terminal, wired through screw terminals torqued to 1 N·m on the control circuit. Main terminals are IP20 per IEC 60529 / IEC 60947-1, so finger-safe but not dust- or water-protected — cabinet mounting is mandatory. There is no integrated electronic overload on this PSR9; ABB pairs it with an MS116 6.30…10.00 thermal overload block for the motor protection line. Run signal relay is present (green LED), fault, overload and by-pass signal relays are not — a status-only device, not a fault annunciator. ## Ambient and connection envelope Operation is rated -25…+60 °C ambient. Main-circuit and supply-circuit connecting capacity is rigid 1/2 x 0.75…2.5 mm²; control circuit takes 1 x 0.75…2.5 mm². The UL/CSA frame rating is 2 Hp at 200…208 V AC three-phase, with control-circuit tightening torque 8.9 in·lb on the UL side. ## Compliance paperwork RoHS compliance follows EU Directive 2011/65/EU and Amendment 2015/863 of 22 July 2019; the part is WEEE Category 5 small equipment and is sold Business-To-Business, not through consumer channels. A FiledBusPlug fieldbus connection is optional, not fitted by default — a Modbus or anybus add-on would be a separate order line against this PSR9 base.","metaTitle":"ABB 1SFA896105R1100 PSR9 Softstarter, 208-600 V AC","metaDescription":"ABB 1SFA896105R1100 PSR9 softstarter with 0–20 s voltage ramp, 208–600 V AC and 24 V AC/DC control. Specs, fit notes, and RFQ sourcing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"0 ... 20 second [unit of time]","Communication":"FiledBusPlug(Optional)","Terminal Type":"Screw Terminals","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSR9","Tightening Torque":"Control Circuit 1 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS116 6.30 ... 10.00","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"No","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"40 ... 70 %","Popular Downloads/EPLAN Data":"9AAC129234_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"100 ... 60 %","Connecting Capacity Main Circuit":"Rigid 1/2 x 0.75 ... 2.5 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"24 V AC/DC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1/2 x 0.75 ... 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Connecting Capacity Control Circuit":"1 x 0.75 ... 2.5 mm²","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 2 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 8.9 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132076M9901","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 2.2 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"9 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$243.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bededf4654e7b58af407c55d7b671138.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896105R1100/alternatives.json"},"ai":{"faq":[{"question":"What is the closest functional second-source to 1SFA896105R1100?","answer":"The closest functional alternative in the same PSR line is the 1SFA896106R1100, with 1SFA896104R1100 and 1SFA896104R7000 as adjacent PSR9 frames. Treat them as the same family only after verifying the matching motor current and voltage class — not as drop-in equivalents."},{"question":"What is 1SFA896105R1100's listed function on this Softstarter line?","answer":"Soft start with voltage ramp, per the spec entry — the device ramps motor voltage from an adjustable 40…70 % initial level to full line over 0…20 s."},{"question":"What is 1SFA896105R1100's listed ramp time?","answer":"0…20 seconds, user-adjustable. Pick a ramp that holds starting current under the 4xIe for 6s envelope for the driven load."},{"question":"Will 1SFA896105R1100 drop into a panel specified around 1SFA896106R1100 without rewiring?","answer":"Both are PSR9 soft starters in the same wiring topology — same 24 V AC/DC control supply and same screw-terminal main circuit layout — but the current class differs between the two PSR codes. Verify the motor FLA and the matching MS116 overload range before swapping; do not treat them as a like-for-like cross."},{"question":"What compliance documentation does ABB provide for 1SFA896105R1100?","answer":"RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 of 22 July 2019; WEEE Category 5 (small equipment); sold Business-To-Business. UL/CSA rating to 2 Hp at 200…208 V AC three-phase is stated."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896105R1100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896105R1100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}