{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896106R1100","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896106R1100","canonicalUrl":"https://aoctrl.com/abb/1SFA896106R1100","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896106R1100","rawCanonicalId":null},"summary":{"shortDescription":"ABB, PSR12 series, softstarter, order code 1SFA896106R1100, 208... 600 V AC, 24 V AC/DC control supply, 0... 20 second ramp time.","salesMarkdown":"## Functional envelope The ABB 1SFA896106R1100 is a PSR12 softstarter with voltage ramp start, 0... 20 second ramp time, and adjustable initial voltage during start of 40... 70 % with a step-down special ramp of 100... 60 %. Starting capacity is rated 4xIe for 6s, so it handles the inrush profile of a standard induction motor within the PSR frame class. Control supply is 24 V AC/DC, and the device runs on 208... 600 V AC at 50/60 Hz, covering common industrial mains from a single unit. ## Overload coordination and signaling Electronic overload is not integrated and the unit has no current limit function, so protection is specified separately: the data sheet recommends an ABB MS132 10.00... 16.00 overload. Wire that breaker upstream and coordinate its trip class with the softstarter's 4xIe for 6s starting capacity. A run signal relay is present; fault, by-pass, and overload signal relays are not. If the panel logic expects a fault contact, plan to source that from the upstream MS132 rather than from the softstarter itself. ## Fieldbus and wiring Communication is via an optional FieldBusPlug; the base unit ships without a fieldbus interface. Terminals are screw type, main circuit rigid 1/2 x 0.75... 2.5 mm², control circuit 1 x 0.75... 2.5 mm², control-circuit tightening torque 1 N·m. Main terminals IP20. ## Environment and compliance Operation is rated -25... +60 °C ambient, service factor 100 %. The unit is RoHS compliant following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019, WEEE category 5 small equipment, B2B.","metaTitle":"ABB 1SFA896106R1100 PSR12 Softstarter, 208-600 V AC","metaDescription":"ABB 1SFA896106R1100 PSR12 softstarter, soft start with voltage ramp, 0–20 s ramp time, 208–600 V AC, 24 V AC/DC control. RoHS compliant. RFQ for stock.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"0 ... 20 second [unit of time]","Communication":"FiledBusPlug(Optional)","Terminal Type":"Screw Terminals","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSR12","Tightening Torque":"Control Circuit 1 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS132 10.00 ... 16.00","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"No","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"40 ... 70 %","Popular Downloads/EPLAN Data":"9AAC129235_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"100 ... 60 %","Connecting Capacity Main Circuit":"Rigid 1/2 x 0.75 ... 2.5 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"24 V AC/DC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1/2 x 0.75 ... 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Connecting Capacity Control Circuit":"1 x 0.75 ... 2.5 mm²","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 3 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 8.9 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132076M9901","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 3 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"12 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$274.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0ce3ab879602b30e411a4868dc469c8a.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896106R1100/alternatives.json"},"ai":{"faq":[{"question":"What is the listed function of 1SFA896106R1100?","answer":"Soft start with voltage ramp, part of the ABB PSR12 softstarter line."},{"question":"What is the ramp time on 1SFA896106R1100?","answer":"0... 20 second, with initial voltage during start adjustable from 40... 70 %."},{"question":"What overload protection does 1SFA896106R1100 require?","answer":"No integrated electronic overload; ABB recommends MS132 10.00... 16.00 wired upstream for motor protection coordination."},{"question":"What compliance documentation does ABB provide for 1SFA896106R1100?","answer":"RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019; WEEE Category 5 small equipment, B2B; rated to IEC 60529, IEC 60947-1, EN 60529 for terminal protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896106R1100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896106R1100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}