{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896114R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896114R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA896114R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896114R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB PSR85 soft starter, voltage ramp with 0–20 s ramp time, 208–600 V AC operational, 100–240 V AC control supply, order code 1SFA896114R7000.","salesMarkdown":"The ABB 1SFA896114R7000 is a PSR85-class soft starter that ramps motor voltage from an adjustable initial level to full line, sized for a 208–600 V AC operational envelope and a starting capacity of 4xIe for 6s at maximum rated current Ie. It is a voltage-ramp unit, not a current-limit device: the current-limit function is absent, and overload protection is specified externally as the ABB MS495 70…90 thermal overload. ## Ramp profile and what the integrator sets Ramp time spans 0…20 s, the initial voltage during start is adjustable from 40…70 %, and a step-down special ramp covers 100…60 %, so soft-stop behavior is configurable on the same ramp setting rather than as a separate parameter. ## Control wiring and supply Main circuit uses bars with rigid cable capacity 1x 10…95 mm²; the supply and control terminal blocks accept 1 x 0.75…2.5 mm² rigid conductors. ## Status outputs the field tech sees Run signal relay, bypass signal relay, and three green LEDs (running R, ramping up/down, completed start ramp) provide the local status picture; fault signal and overload signal relays are not present, so those conditions must be read via the optional FieldBusPlug or external wiring. ## Environment and compliance Operation is rated -25…+60 °C ambient at 50/60 Hz, main terminals carry IP10 per IEC 60529 / IEC 60947-1, and the part is RoHS-compliant under EU Directive 2011/65/EU with Amendment 2015/863 dated July 22, 2019. ## Sourcing posture No lifecycle status entry is carried on this order code, so production status should be confirmed against current ABB PSR85 line information before committing the BOM; quoted against an RFQ to the usual ABB soft-starter channel, with the optional FieldBusPlug and the MS495 70…90 external overload specified as separate line items if the application needs bus connectivity or motor thermal protection.","metaTitle":"ABB 1SFA896114R7000 PSR85 Softstarter, 600 V","metaDescription":"ABB 1SFA896114R7000 PSR85 soft starter, voltage ramp with 0–20 s ramp, 208–600 V AC operational, 100–240 V AC control supply.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"0 ... 20 second [unit of time]","Communication":"FiledBusPlug(Optional)","Terminal Type":"Main Circuit: Bars","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSR85","Tightening Torque":"Control Circuit 0.6 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS495 70 ... 90","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"40 ... 70 %","Popular Downloads/EPLAN Data":"9AAC157494_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"100 ... 60 %","Connecting Capacity Main Circuit":"Rigid 1x 10 ... 95 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 240 V AC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1 x 0.75 ... 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Connecting Capacity Control Circuit":"1 x 0.75 ... 2.5 mm²","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 25 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 5.3 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132033M0001","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 22 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"85 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$909.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/415d81c0c8184ae57a85592f404ea5b4.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896114R7000/alternatives.json"},"ai":{"faq":[{"question":"What is the listed function of the 1SFA896114R7000?","answer":"Soft start with voltage ramp — a voltage-ramp soft starter, not a current-limit device, rated for 208…600 V AC operation."},{"question":"What is the ramp time on the 1SFA896114R7000?","answer":"Ramp time is 0…20 s, with an initial voltage during start of 40…70 % and a step-down special ramp of 100…60 %."},{"question":"Does the 1SFA896114R7000 have built-in overload protection?","answer":"No integrated electronic overload is provided; ABB specifies the external MS495 70…90 thermal overload for motor protection on this unit."},{"question":"What compliance documentation does ABB provide for the 1SFA896114R7000?","answer":"The part is declared RoHS-compliant under EU Directive 2011/65/EU and Amendment 2015/863 dated July 22, 2019, and carries an IP10 main-terminal rating to IEC 60529 / IEC 60947-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896114R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896114R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}