{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896115R1100","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896115R1100","canonicalUrl":"https://aoctrl.com/abb/1SFA896115R1100","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896115R1100","rawCanonicalId":null},"summary":{"shortDescription":"ABB PSR105 soft starter, order code 1SFA896115R1100, soft start with voltage ramp, 208–600 V AC operating range, 24 V AC/DC control supply, ramp time 0–20 s.","salesMarkdown":"The ABB 1SFA896115R1100 is a member of the PSR105 soft-starter line, sized to deliver a soft start with voltage ramp across a 208 … 600 V AC operating range at 50/60 Hz. The ramp is the only start profile on board — there is no current-limit function and no switch for inside-delta connection — so this unit is intended for in-line (non-six-wire) motor starts where a controlled voltage ramp is enough. ## Start profile the panel will be tuned to Ramp time is adjustable across 0 … 20 second, and the initial voltage during start is settable from 40 … 70 %. A complementary step-down special ramp is also available, 100 … 60 %. That gives the commissioning engineer two knobs — how long to ramp, and how low to start the voltage — and nothing else: no current-limit means the start current ceiling has to be set downstream. Service factor is 100 %, and there is no integrated electronic overload on the unit. The ABB documentation calls for a recommended MS495 80 … 100 motor protector in series, so the overload function lives outside this enclosure rather than inside it. ## Control power, terminals and wiring Control supply is 24 V AC/DC, with a rated control circuit voltage of 24 V DC and a tightening torque on the control circuit of 0.6 N·m. The control and supply wiring takes rigid conductor 1 x 0.75 … 2.5 mm². Main-circuit connection is by bars — not lugs or ring terminals — and the main terminals are rated IP10 per IEC 60529 / IEC 60947-1, which is a finger-safe rating only and is not a panel-front rating. ## Signal relays and fieldbus slice On the signalling side, the unit carries a run signal relay and a by-pass signal relay, but no fault signal relay and no overload signal relay. Status indication is two green LEDs — running R and ramping up/down. A FieldBusPlug is offered as an optional add-on for comms, not built in. ## Compliance pack on the nameplate The unit is declared compliant with EU Directive 2011/65/EU and Amendment 2015/863 dated July 22, 2019. UL/CSA horsepower rating is 30 Hp at 200 … 208 V AC three-phase. The WEEE classification is category 5 (small equipment, no external dimension more than 50 cm) and the trade channel is Business To Business.","metaTitle":"ABB 1SFA896115R1100 PSR105 Softstarter, 208–600 V AC","metaDescription":"ABB PSR105 soft starter 1SFA896115R1100: voltage-ramp start, 208–600 V AC, 24 V AC/DC control, 0–20 s ramp. Specified to BOM against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"0 ... 20 second [unit of time]","Communication":"FiledBusPlug(Optional)","Terminal Type":"Main Circuit: Bars","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSR105","Tightening Torque":"Control Circuit 0.6 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS495 80 ... 100","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Material Compliance/SCIP":"1caf577d-084a-43ed-a6ea-ef420754c09b China","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"40 ... 70 %","Popular Downloads/EPLAN Data":"9AAC157495_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"100 ... 60 %","Connecting Capacity Main Circuit":"Rigid 1x 6 ... 95 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"24 V AC/DC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1 x 0.75 ... 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Connecting Capacity Control Circuit":"1 x 0.75 ... 2.5 mm²","Material Compliance/Simplified SCIP":"d2b5998d-e346-4f05-964d-2780655f6d37 Hungary","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 30 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 5.3 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132079M9901","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 30 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"105 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,192.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3c9674aa579b0f0852052c3194e0a225.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896115R1100/alternatives.json"},"ai":{"faq":[{"question":"What is the listed function and ramp time?","answer":"Function is soft start with voltage ramp; ramp time is adjustable across 0 … 20 second, with initial voltage during start settable from 40 … 70 % and a step-down special ramp of 100 … 60 %."},{"question":"What overload protection does it carry?","answer":"There is no integrated electronic overload on the unit. ABB's documentation recommends an MS495 80 … 100 motor protector in series with the soft starter."},{"question":"What control supply does it need?","answer":"24 V AC/DC, with a rated control circuit voltage of 24 V DC and a control-circuit tightening torque of 0.6 N·m. Control and supply wiring takes rigid 1 x 0.75 … 2.5 mm²."},{"question":"What signal relays are available?","answer":"A run signal relay and a by-pass signal relay are provided; a fault signal relay and an overload signal relay are not provided on this model."},{"question":"What compliance documentation ships with it?","answer":"RoHS compliance is declared per EU Directive 2011/65/EU and Amendment 2015/863 (22 July 2019). UL/CSA rating is 30 Hp at 200 … 208 V AC three-phase. WEEE category is 5 (small equipment) and the trade channel is Business To Business."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896115R1100","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896115R1100 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}