{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896204R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896204R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA896204R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896204R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB PSRC6-600-70, 1SFA896204R7000, soft starter with voltage ramp, rated 208-600 V AC, control supply 100-240 V AC, IP20 main terminals.","salesMarkdown":"The ABB 1SFA896204R7000 is a PSRC6-600-70 soft starter that applies a voltage ramp to limit inrush current during motor start. The fixed ramp time means the acceleration profile is preset — not adjustable in the field — so it suits applications where the load characteristic is consistent and the starting torque requirement is known at commissioning. The initial voltage during start is also a fixed setting, which sets the breakaway torque applied to the load before the ramp begins. For a given motor and load pair, these fixed parameters either work or they don't; there is no field tuning. Rated operational voltage spans 208 to 600 V AC, three-phase, at 50/60 Hz. The control supply is 100-240 V AC, and a separate 24 V DC control circuit is available for the logic interface — useful when integrating into a 24 V DC control panel architecture. The control circuit terminals tighten to 1 N·m (8.9 in·lb per the UL/CSA listing). Starting capacity is 4x Ie for 6 seconds. The PSRC6 mounts in a standard control panel. Main terminals are rated IP20 per IEC 60529 and IEC 60947-1, so the unit is touch-safe when installed inside a closed enclosure. Screw terminals on the main circuit accept rigid conductors from 2 x 0.75 to 1.5 mm²; the supply circuit accepts 1 x 0.75 to 2.5 mm² rigid. An optional FiledBusPlug communication module can be added for network integration, but the base unit has no onboard fieldbus. A green LED indicates running, ramping up/down, and completed start ramp — three distinct states visible through the enclosure window. A run signal relay is included (fault and by-pass signal relays are not). The unit does not have an integrated electronic overload; ABB recommends an external MS116 manual motor starter sized 4.00 to 10.00 A for overload protection. This is a common pairing in ABB's motor-starting ecosystem.","metaTitle":"ABB PSRC6-600-70 1SFA896204R7000 Soft Starter, 208-600V AC","metaDescription":"ABB PSRC6-600-70 soft starter 1SFA896204R7000. Soft start with voltage ramp, 208-600V AC, 100-240V AC control supply. Current lifecycle stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"Fixed setting","Communication":"FiledBusPlug(Optional)","Terminal Type":"Screw Terminals","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSRC6","Tightening Torque":"Control Circuit 1 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS116 4.00 ... 10.00","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"No","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"Fixed setting","Popular Downloads/EPLAN Data":"9AAC172767_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"Fixed setting","Connecting Capacity Main Circuit":"Rigid 2 x 0.75 ... 1.5 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 240 V AC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1 x 0.75 ... 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 1 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 8.9 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132041M0001","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 1.5 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"6.8 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa896204r7000","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896204R7000/alternatives.json"},"ai":{"faq":[{"question":"What is the function of the 1SFA896204R7000?","answer":"The 1SFA896204R7000 is a soft starter with voltage ramp — it limits motor inrush current by ramping the applied voltage from a fixed initial level to full line voltage over a fixed time period."},{"question":"What overload protection is recommended for the 1SFA896204R7000?","answer":"ABB recommends an MS116 manual motor starter rated 4.00 to 10.00 A for external overload protection, as the soft starter does not have an integrated electronic overload."},{"question":"What is the starting capacity of the PSRC6-600-70?","answer":"The starting capacity is 4x the rated motor current Ie for 6 seconds."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896204R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896204R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}