{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896209R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896209R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA896209R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896209R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB PSRC30-600-70 soft starter, Function Soft start with voltage ramp, Rated Operational Voltage 208... 600 V AC, Starting Capacity 4xIe for 6s, lifecycle_stage current.","salesMarkdown":"The ABB 1SFA896209R7000 is a PSRC30-600-70 soft starter that uses a voltage ramp to bring motors up to speed gradually. It's rated for 208 to 600 V AC three-phase supplies and can deliver 4x the motor's rated current (Ie) for 6 seconds during start-up — enough headroom for most standard induction motors on pumps, fans, or light conveyors. The control circuit runs on 24 V DC, while the main control supply accepts 100 to 240 V AC. Screw terminals on both main and control circuits keep wiring straightforward for panel builders. The 4xIe for 6 seconds starting capacity handles motor start-up current for that duration. Mount it inside a panel with a suitable enclosure rating for the environment — standard practice for a soft starter in a motor control center. ABB recommends pairing it with an MS132 manual motor starter in the 25 to 32 A range for overload protection, since this soft starter doesn't have built-in electronic overload. That's a common setup — the MS132 handles short-circuit and overload, the soft starter handles the ramp. Screw terminals accept rigid conductors up to 2 x 1.5 mm² on both main and supply circuits. Tighten control circuit terminals to 0.6 N·m (5.3 in·lb for UL/CSA versions). The optional FiledBusPlug lets you connect to a fieldbus network without hardwiring discrete I/O for start/stop and status signals. Three signal LEDs on the front — green for ramping up/down, green for run, green for completed start ramp — give a quick visual on the starter's state without needing a screen or HMI.","metaTitle":"1SFA896209R7000 ABB PSRC30-600-70 Soft Starter, 208-600 V AC","metaDescription":"ABB PSRC30-600-70 soft starter with voltage ramp, rated 208-600 V AC, 4xIe for 6s starting capacity. Current lifecycle stage. Screw terminals, IP20.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"Fixed setting","Communication":"FiledBusPlug(Optional)","Terminal Type":"Screw Terminals","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSRC30","Tightening Torque":"Control Circuit 0.6 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS132 25 ... 32","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"Fixed setting","Popular Downloads/EPLAN Data":"9AAC172772_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"Fixed setting","Connecting Capacity Main Circuit":"Rigid 2 x 0.75 ... 1.5 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 240 V AC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 2 x 0.75 ... 1.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 7.5 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 5.3 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132042M0001","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 7.5 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"30 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa896209r7000","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896209R7000/alternatives.json"},"ai":{"faq":[{"question":"Does 1SFA896209R7000 include built-in overload protection?","answer":"No, it does not have integrated electronic overload protection. ABB recommends pairing it with an MS132 manual motor starter in the 25 to 32 A range for overload and short-circuit protection."},{"question":"What is 1SFA896209R7000's starting capacity?","answer":"It delivers 4x the motor's rated current (Ie) for 6 seconds during start-up — enough for standard induction motors on pumps, fans, and conveyors."},{"question":"Where can I buy 1SFA896209R7000?","answer":"This part is sourced to order against a request for quote. Availability and pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896209R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896209R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}