{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896213R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896213R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA896213R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896213R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB, PSRC72 series, soft starter with voltage ramp, 1SFA896213R7000, 20 Hp at 200-208 V AC three-phase (UL/CSA), 100-240 V AC control supply, 24 V DC control circuit.","salesMarkdown":"## Soft start with voltage ramp — PSRC72 The ABB 1SFA896213R7000 is a PSRC72 soft starter that applies a voltage ramp during start, limiting inrush current and mechanical shock to the load. Fixed ramp time and fixed initial voltage mean no field adjustment — set it and commission it. Control supply is 100-240 V AC; the separate 24 V DC control circuit powers the logic and signal relays, keeping the high-voltage path isolated from the low-voltage control wiring. Rated operational voltage covers 208-600 V AC, 50/60 Hz. The UL/CSA horsepower rating lands at 20 Hp on 200-208 V three-phase — that's the figure to match against your motor nameplate for North American installations. Starting capacity is 4x Ie for 6 seconds, enough for standard induction motor start profiles without oversizing the starter. Main circuit connections are bars; control wiring terminates with a torque spec of 0.6 N·m (5.3 in·lb for UL/CSA). ## Signal and protection Built-in run signal relay and by-pass signal relay give feedback for PLC or status lamp integration — no fault or overload relay on board. The manufacturer recommends an external overload relay (MS495 57-75) for motor protection. Green LEDs indicate running, ramping up/down, and completed start ramp, so panel walk-throughs are quick: one glance tells you the state. RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863. WEEE category 5 (Small Equipment). Degree of protection on main terminals is IP10 per IEC 60529, IEC 60947-1, EN 60529 — basic finger-safety, not washdown. CAD dimensional drawing (2CDC001079B0201) and instruction manual (1SFC132044M0001) are available for download.","metaTitle":"ABB 1SFA896213R7000 PSRC72 Soft Starter, 20 Hp at 200-208 V","metaDescription":"ABB PSRC72 soft starter with voltage ramp, rated 20 Hp at 200-208 V AC (UL/CSA). 100-240 V AC control supply, 24 V DC control circuit. Current lifecycle. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"Fixed setting","Communication":"FiledBusPlug(Optional)","Terminal Type":"Main Circuit: Bars","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSRC72","Tightening Torque":"Control Circuit 0.6 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS495 57 ... 75","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"Fixed setting","Popular Downloads/EPLAN Data":"9AAC172776_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"Fixed setting","Connecting Capacity Main Circuit":"Rigid 2 x 0.75 ... 1.5 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 240 V AC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1 x 0.75 ... 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 20 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 5.3 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132044M0001","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 22 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"72 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa896213r7000","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896213R7000/alternatives.json"},"ai":{"faq":[{"question":"What does 'soft start with voltage ramp' mean on this component?","answer":"It means the starter applies a gradually increasing voltage to the motor during start, reducing inrush current and mechanical torque shock. The ramp time and initial voltage are fixed — no field adjustment."},{"question":"What compliance documentation does ABB provide for 1SFA896213R7000?","answer":"RoHS compliance per EU Directive 2011/65/EU and Amendment 2015/863 is documented. WEEE category 5 applies. CAD drawing (2CDC001079B0201) and instruction manual (1SFC132044M0001) are available."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896213R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896213R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}