{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896214R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896214R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA896214R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896214R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB PSRC85 soft starter, 1SFA896214R7000, soft start with voltage ramp, 208-600 V AC, 25 Hp at 200-208 V, 4x Ie for 6s, current production.","salesMarkdown":"The ABB 1SFA896214R7000 is a PSRC85 soft starter with a voltage-ramp start profile, sized for three-phase induction motors across a 208-600 V AC supply. It delivers 4x rated motor current for 6 seconds during start, with a fixed ramp time and fixed initial voltage — no field-adjustable parameters, so the application must match the factory setting. The 25 Hp rating at 200-208 V AC (UL/CSA) gives a quick fit check for North American 208 V distribution panels. Control power is dual-range: 100-240 V AC for the coil, and a separate 24 V DC control circuit for logic inputs. The 4x Ie for 6 seconds starting capacity is the key motor-match number: it means the soft starter can handle a motor with a locked-rotor current up to four times its rated full-load current, as long as the start completes within six seconds. If your motor has a higher inrush or a longer acceleration time (high-inertia loads like fans or conveyors), this unit will trip on the start profile. The fixed ramp and fixed initial voltage mean you cannot soften the start further — the part is designed for standard, repeatable starts where the load doesn't change. The main terminals carry an IP10 rating per IEC 60529 — finger-safe against solid objects but not sealed against moisture, so the unit must live inside a panel with at least IP54 enclosure protection if washdown or condensation is present. ## Integration notes Main circuit connections use bars, accepting rigid 1 x 0.75-2.5 mm² conductors. Control circuit terminals require 0.6 N·m (5.3 in·lb) torque. The optional FieldBusPlug communication module can be added for network integration, but the base unit has no onboard fieldbus. Run signal and bypass signal relays are included; fault and overload signal relays are not — plan external indication if needed. The recommended overload relay is the MS495 series, set to 70-90 A range.","metaTitle":"ABB 1SFA896214R7000 PSRC85 Soft Start, 208-600 V AC, 25 Hp","metaDescription":"ABB PSRC85 soft starter 1SFA896214R7000, 208-600 V AC, 25 Hp at 200-208 V, 4x Ie for 6s start. Current production, sourced to order. RoHS, UL/CSA.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"Fixed setting","Communication":"FiledBusPlug(Optional)","Terminal Type":"Main Circuit: Bars","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSRC85","Tightening Torque":"Control Circuit 0.6 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS495 70 ... 90","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"Fixed setting","Popular Downloads/EPLAN Data":"9AAC172777_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"Fixed setting","Connecting Capacity Main Circuit":"Rigid 1 x 0.75 ... 2.5 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 240 V AC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1 x 0.75 ... 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 25 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 5.3 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132044M0001","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 22 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"85 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa896214r7000","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896214R7000/alternatives.json"},"ai":{"faq":[{"question":"What is the function of 1SFA896214R7000?","answer":"It is a soft starter with voltage ramp — it gradually increases voltage to the motor during start, reducing mechanical shock and electrical inrush. Ramp time and initial voltage are fixed, not adjustable."},{"question":"What is the starting capacity of this soft starter?","answer":"It can deliver 4 times the rated motor current (4x Ie) for up to 6 seconds during start. This suits standard-acceleration loads; high-inertia or long-start applications may trip the profile."},{"question":"What compliance documentation does ABB provide for 1SFA896214R7000?","answer":"The part is RoHS compliant per EU Directive 2011/65/EU and Amendment 2015/863. UL/CSA horsepower rating is 25 Hp at 200-208 V AC three-phase. Instructions and manuals are available under document 1SFC132044M0001."},{"question":"Where can I buy 1SFA896214R7000 and how is it quoted?","answer":"The 1SFA896214R7000 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896214R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896214R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}