{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA896215R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA896215R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA896215R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA896215R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB PSRC105 soft starter, 1SFA896215R7000, soft start with voltage ramp, 208-600 V AC, 30 Hp UL/CSA, fixed ramp time, 100-240 V AC control supply, 24 V DC control circuit.","salesMarkdown":"## Function and key ratings The ABB 1SFA896215R7000 is a PSRC105 soft starter with voltage ramp, designed to reduce inrush current and mechanical stress during motor start-up. It operates on a fixed ramp time — no field adjustment — so the ramp profile is set at the factory for consistent, repeatable starts. Rated operational voltage spans 208 to 600 V AC at 50/60 Hz, and the UL/CSA horsepower rating is 30 Hp at 200–208 V AC three-phase. The control supply voltage is 100–240 V AC; the control circuit runs on 24 V DC. Main circuit terminals are bars; connecting capacity is rigid 1 x 0.75 to 2.5 mm². Control circuit tightening torque is 0.6 N·m (5.3 in·lb). The supply circuit accepts rigid 2 x 0.75 to 1.5 mm². The unit includes a run signal relay and a by-pass signal relay, but no fault or overload signal relay. Overload protection is recommended via an external MS495 80–100 unit — the starter itself has no integrated electronic overload. Optional FiledBusPlug communication allows integration into a fieldbus network; the starter is not switchable for inside-delta connection. Popular downloads include the EPLAN data (9AAC172778_EPLAN), CAD dimensional drawing (2CDC001079B0201), and instruction manual (1SFC132044M0001).","metaTitle":"ABB 1SFA896215R7000 PSRC105 Soft Starter, 208-600 V AC, 30 H","metaDescription":"ABB PSRC105 soft starter with voltage ramp, rated 208-600 V AC, 30 Hp UL/CSA. Current production. RoHS compliant. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Soft Starters"],"specifications":{"Function":"Soft start with voltage ramp","Ramp Time":"Fixed setting","Communication":"FiledBusPlug(Optional)","Terminal Type":"Main Circuit: Bars","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSRC105","Tightening Torque":"Control Circuit 0.6 N·m","Fault Signal Relay":"No","Overload Protection":"Recommended MS495 80 ... 100","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10","Overload Signal Relay":"No","Current Limit Function":"No","Ambient Air Temperature":"Operation -25 ... +60 °C","Material Compliance/SCIP":"1caf577d-084a-43ed-a6ea-ef420754c09b China","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"Fixed setting","Popular Downloads/EPLAN Data":"9AAC172778_EPLAN","Integrated Electronic Overload":"No","Step Down Voltage Special Ramp":"Fixed setting","Connecting Capacity Main Circuit":"Rigid 1 x 0.75 ... 2.5 mm²","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 240 V AC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 2 x 0.75 ... 1.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Switch for Inside Delta Connection":"No","Material Compliance/Simplified SCIP":"be1ef16f-bfa2-486c-b0de-8799aca7c457 Norway","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 30 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 5.3 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132044M0001","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 6s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 30 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"105 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/1sfa896215r7000","alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA896215R7000/alternatives.json"},"ai":{"faq":[{"question":"What is 1SFA896215R7000's listed function?","answer":"Its function is soft start with voltage ramp, with a fixed ramp time and a fixed initial voltage during start."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA896215R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA896215R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}