{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"1SFA897106R7000","brand":"ABB","brandSlug":"abb","productSlug":"1SFA897106R7000","canonicalUrl":"https://aoctrl.com/abb/1SFA897106R7000","factsUrl":"https://aoctrl.com/api/mcp/products/1SFA897106R7000","rawCanonicalId":null},"summary":{"shortDescription":"ABB PSE60-600-70 Softstarter - 60 A - 208... 600 V AC, torque control, Modbus-RTU, screw terminals.","salesMarkdown":"The 1SFA897106R7000: The ABB PSE60-600-70 is a 60 A soft starter for 208 to 600 V AC motors, with integrated torque control to tailor the starting curve and built-in electronic overload protection. Communication over Modbus-RTU lets the PLC monitor current limit, ramp time, and fault status without hardwired status signals. Rated control voltage is 24 V DC, so it pulls directly from a standard 24 V bus without a separate transformer. The three integrated relays – run, fault, bypass, and overload – each output a clean dry contact for the control system.","metaTitle":"1SFA897106R7000 ABB PSE60-600-70 Softstarter 60A, Modbus-RTU","metaDescription":"ABB PSE60-600-70 soft starter, 60A, 208-600V AC, torque control, Modbus-RTU. Active production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Function":"Soft start with torque control","Ramp Time":"0 ... 30 second [unit of time]","Communication":"Modbus-RTU","Terminal Type":"Screw Terminals","Analog Outputs":"4...20 mA","lifecycle_stage":"current","Run Signal Relay":"Yes","Product Main Type":"PSE60","Tightening Torque":"Control Circuit 0.5 N·m","Fault Signal Relay":"Yes","Overload Protection":"Build-in electronic overload protection","Protection Function":"Electronic overload protection, EOL; Locked rotor protection; Current underload protection","Rated Frequency (f)":"50/60 Hz","By-pass Signal Relay":"Yes","Degree of Protection":"acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00","Overload Signal Relay":"Yes","Current Limit Function":"1.5 ... 7xIe","Ambient Air Temperature":"Operation -25 ... +60 °C","Material Compliance/SCIP":"6528473c-4979-467d-a71c-ecd91610a0bc Sweden","Rated Operational Voltage":"208 ... 600 V AC","Service Factor Percentage":"100 %","Object Classification Code":"Q","Initial Voltage During Start":"30 ... 70 %","Popular Downloads/EPLAN Data":"9AAC170230_EPLAN","Signal Indication Fault (LED)":"Red","Integrated Electronic Overload":"Yes","Step Down Voltage Special Ramp":"No %","Connecting Capacity Main Circuit":"Hole Diameter 8.5 mm","Material Compliance/WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","Rated Control Supply Voltage (Us)":"100 ... 250 V AC","Signal Indication Running R (LED)":"Green","Connecting Capacity Supply Circuit":"Rigid 1 x 2.5","IDEA Granular Category Code (IGCC)":"4740 >> Soft starter","Material Compliance/WEEE B2C / B2B":"Business To Business","Rated Control Circuit Voltage (Uc)":"24 V DC","Signal Indication Protection (LED)":"Yellow","Switch for Inside Delta Connection":"No","Connecting Capacity Control Circuit":"Rigid 1 x 2.5 mm²","Material Compliance/RoHS Information":"Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019","Signal Indication Ramping Up/Down (LED)":"Green","Popular Downloads/CAD Dimensional Drawing":"2CDC001079B0201","Technical UL/CSA/Horsepower Rating UL/CSA":"(200 ... 208 V AC) Three Phase 20 Hp","Technical UL/CSA/Tightening Torque UL/CSA":"Control Circuit 4.4 in·lb","Popular Downloads/Instructions and Manuals":"1SFC132427M0201","Signal Indication Completed Start Ramp (LED)":"Green","Starting Capacity at Maximum Rated Current Ie":"4xIe for 10s","Rated Operational Power - In-Line Connection (Pe)":"(230 V) 15 kW","Technical UL/CSA/Maximum Operating Voltage UL/CSA":"Main Circuit 600 V","Popular Downloads/Data Sheet, Technical Information":"1SFC132012C0201","Popular Downloads/Instructions and Manuals (Part 2)":"1SFC132057M0201","Popular Downloads/Instructions and Manuals (Part 3)":"1SFC132060M0201","Rated Operational Current - In-Line Connection (Ie)":"60 A","Material Compliance/Toxic Substances Control Act - TSCA":"2CMT2023-006524","Material Compliance/Conflict Minerals Reporting Template (CMRT)":"9AKK108467A5658"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,061.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0175e1c8cf94c0f52e82d040fb9dbca0.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/1SFA897106R7000/alternatives.json"},"ai":{"faq":[{"question":"What is the listed title and function of this part?","answer":"Listed title: PSE60-600-70 Softstarter - 60 A - 208... 600 V AC. Function: soft start with torque control."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/1SFA897106R7000","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/1SFA897106R7000 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}