{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"21553","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"21553","canonicalUrl":"https://aoctrl.com/schneider/21553","factsUrl":"https://aoctrl.com/api/mcp/products/21553","rawCanonicalId":null},"summary":{"shortDescription":"iDPN - circuit breaker - iDPN N - 1P + N - 2A - C curve","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"2.8 in (70 mm)","Range":"Clario","Width":"0.7 in (18 mm)","Height":"3.1 in (80 mm)","Category":"01078-DE2 MISC","Standards":"EN 60898 IEC 60947-2","Curve code":"C","9 Mm Pitches":"2","Control Type":"Toggle","Network type":"AC","Product name":"IDPN","Mounting Mode":"Clip-on","Tropicalisation":"2 IEC 60068-1","lifecycle_stage":"unknown","Limitation class":"3 EN 60898-1","Local signalling":"ON/OFF indication","Mounting Support":"35 mm symmetrical DIN rail","Neutral position":"Left","Range of Product":"Clario","Breaking capacity":"6000 A Icn 230 V AC 50/60 Hz EN 60898-1 10 kA Icu 230 V AC 50/60 Hz EN/IEC 60947-2","Device short name":"iDPN N","Network Frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % 131 °F (55 °C)","Tightening torque":"17.7 lbf.in (2 N.m)","Device Application":"Distribution","Line Rated Current":"2 A","Operating altitude":"6561.68 ft (2000 m)","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Nbr. of units in pkg.":"1","Wire stripping length":"0.5 in (13 mm)","Connections - terminals":"Tunnel type terminals 0.0005...0.02 in² (0.33...10 mm²) flexible Tunnel type terminals 0.001...0.02 in² (0.75...16 mm²) rigid","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or Component Type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Ambient Air Temperature for Storage":"-40...158 °F (-40...70 °C)","Ambient air temperature for operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"6000 A 100 % x Icn at 230 V AC 50/60 Hz conforming to EN 60898-1","[Uimp] rated impulse withstand voltage":"4 kVEN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$68.58","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/21553/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/21553","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/21553 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}