{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"28629","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"28629","canonicalUrl":"https://aoctrl.com/schneider/28629","factsUrl":"https://aoctrl.com/api/mcp/products/28629","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker NG160N - TMD - 16 A - 3 poles 3d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"82.5 mm","Width":"90 mm","Height":"120 mm","Standards":"IEC 60947-3","Control type":"Toggle","Network type":"AC","Mounting mode":"Clipped","Trip unit name":"TM-D","Protection type":"Overload protection (thermal) Short-circuit protection (magnetic)","lifecycle_stage":"unknown","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Range of product":"NG160","Trip unit rating":"16 A","Breaking capacity":"10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 16 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"NG160N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"16 A at 40 °C","Downside connection":"Front","Circuit breaker name":"NG160N","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles 440 V","Mechanical durability":"10000 cycles","Breaking capacity code":"N","Connections - terminals":"Tunnel type terminals","Earth-leakage protection":"Separate block","Magnetic tripping current":"600 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes","Protected poles description":"3t","Long time pick-up adjustment type Ir":"Fixed","[Ics] rated service breaking capacity":"30 kA at 220/240 V AC 50/60 Hz 7.5 kA at 500 V AC 50/60 Hz 12 kA at 440 V AC 50/60 Hz 18.75 kA at 380/415 V AC 50/60 Hz"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1b79026e9c176a0598dc508aee6f90d5.pdf","sourceUrl":"https://www.se.com/ie/en/product/28629/circuit-breaker-ng160n-tmd-16-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/28629/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/28629","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/28629 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}