{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"29472","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"29472","canonicalUrl":"https://aoctrl.com/schneider/29472","factsUrl":"https://aoctrl.com/api/mcp/products/29472","rawCanonicalId":null},"summary":{"shortDescription":"remote control source changeover. Transferpact. ACP plate and UA controller. 220 VAC to 240 VAC 50/60 Hz","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Standards":"IEC 947-5-1","Input type":"Contacts customer voluntary order to transfer to source R","Output type":"Contacts customer: indication of operation in automatic or stop mode","Test function":"By pressing the test button on the front of the controller","Operating mode":"Automatic operation Forced operation on normal source Stop (both normal and replacement source off) Forced operation on replacement source","Selection modes":"Circuit breaker on R Circuit breaker on N","lifecycle_stage":"unknown","Local signalling":"On Off Fault trip","Range of product":"NSX100...250 Compact NS100...630 MasterPact NW MasterPact NT NSX400...630 Compact NS630b...1600","Device short name":"ACP + UA","Interlocked device":"MasterPact NT NSX400...630 MasterPact NW NSX100...250 Compact NS100...630 Compact NS630b...1600","Complementary function":"Voluntary transfer to replacement source (e.g. energy management commands) Forced normal source if replacement source not operational during peak-tariff Selection of type of normal source (single-phase or three-phase) Setting of maximum startup time for the replacement source Additional contact: transfer to replacement source only if contact is closed","IK degree of protection":"Front: IK07 conforming to EN 50102","IP degree of protection":"IP20 connectors: conforming to EN 60529 IP40 front: conforming to EN 60529 IP30 side: conforming to EN 60529","Product or component type":"Interface and control unit","[Us] rated supply voltage":"220...240 V AC at 50/60 Hz","[Ie] rated operational current":"AC-12: 4 A AC 440 V AC-12: 5 A AC 380/415 V AC-12: 8 A AC 110 V AC-12: 8 A AC 220/240 V AC-12: 8 A AC 24 V AC-12: 8 A AC 48 V AC-13: 6 A AC 110 V AC-13: 6 A AC 220/240 V AC-13: 7 A AC 24 V AC-13: 7 A AC 48 V AC-14: 4 A AC 110 V AC-14: 4 A AC 220/240 V AC-14: 5 A AC 24 V AC-14: 5 A AC 48 V AC-15: 3 A AC 220/240 V AC-15: 4 A AC 110 V AC-15: 5 A AC 24 V AC-15: 5 A AC 48 V DC-12: 0.4 A DC 250 V DC-12: 0.6 A DC 110 V DC-12: 2 A DC 48 V DC-12: 8 A DC 24 V DC-13: 2 A AC 24 V","Accessory / separate part category":"Interlocking accessory","[Ith] conventional free air thermal current":"8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$967.74 – $1,443.01","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4c80c50b1b3d03a67ebdb8b3bae5fbc3.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/29472/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/29472","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/29472 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}