{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"29587","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"29587","canonicalUrl":"https://aoctrl.com/schneider/29587","factsUrl":"https://aoctrl.com/api/mcp/products/29587","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker Compact NS100N - TMD - 30 A - 1 pole 1d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"35 mm","Height":"161 mm","Standards":"IEC 60947-2","Control type":"Toggle","Network type":"DC AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection (thermal) Short-circuit protection (magnetic)","lifecycle_stage":"unknown","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"Compact NS100...630","Trip unit rating":"30 A at 40 °C","Breaking capacity":"25 kA at 240 V AC 50/60 Hz conforming to NEMA AB1 HIC 25 kA at 277 V AC 50/60 Hz conforming to NEMA AB1 HIC 25 kA Icu at 220 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 277 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 250 V DC 1P conforming to IEC 60947-2 50 kA Icu at 48/125 V DC 1P conforming to IEC 60947-2","Device short name":"Compact NS100N","Network frequency":"50/60 Hz","Poles description":"1P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"100 A at 40 °C 100 A at 65 °C","Downside connection":"Front","Circuit breaker name":"Compact NS100N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"10000 cycles 277 V AC 50/60 Hz In conforming to IEC 60947-2 20000 cycles 277 V AC 50/60 Hz In/2 conforming to IEC 60947-2","Mechanical durability":"20000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 conforming to IEC 60529","Magnetic tripping current":"800 A 1250 A 190 A 260 A 640 A 300 A 1000 A 500 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Protected poles description":"1t","[Ui] rated insulation voltage":"750 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"250 V DC conforming to IEC 60947-2 277 V AC 50/60 Hz conforming to IEC 60947-2","Long time pick-up adjustment range":"0.8...1 x In","Ambient air temperature for storage":"-50...85 °C","Long time pick-up adjustment type Ir":"Fixed","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"25 kA at 220 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 277 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 250 V DC conforming to IEC 60947-2 50 kA at 48/125 V DC conforming to IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7ba9e9d978f789db90451967b778df69.pdf","sourceUrl":"https://www.se.com/ie/en/product/29587/circuit-breaker-compact-ns100n-tmd-30-a-1-pole-1d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/29587/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/29587","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/29587 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}