{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"2TLA050202R0332","brand":"ABB","brandSlug":"abb","productSlug":"2TLA050202R0332","canonicalUrl":"https://aoctrl.com/abb/2TLA050202R0332","factsUrl":"https://aoctrl.com/api/mcp/products/2TLA050202R0332","rawCanonicalId":null},"summary":{"shortDescription":"ABB LineStrong2 pull wire emergency stop switch, 2TLA050202R0332, IP67 die-cast yellow enclosure, 80 m wire span, IEC/EN60947-5-1 double break contacts.","salesMarkdown":"The ABB 2TLA050202R0332 is a LineStrong2 pull-wire emergency stop switch — the type you run along a conveyor, transfer line, or machine cell where an operator needs to trigger a stop from any point along the span, not just a single pushbutton station. IP67 enclosure means the die-cast painted yellow housing and the contacts inside hold up to washdown, dust, and outdoor exposure — food processing, automotive paint lines, or aggregate handling are the usual installs. The wire span reaches up to 80 m, so one switch covers a long straight section without needing a second pull unit. The contacts are IEC/EN60947-5-1 double break Type Zb with silver contact material — that standard covers control-circuit switching for safety functions, so the contacts are rated for the reliability and forced opening required in emergency-stop circuits. Double break opens each pole in two places, aiding arc extinction on DC or low-AC voltage control circuits. ## Mounting and enclosure integration Mounts with four M5 bolts through the housing flanges — no DIN rail, so it bolts directly to a machine frame or stand-off bracket. Three M20 x 1.5 conduit entries give you room for incoming and outgoing cable runs plus a spare for a second pull direction or a signal lamp. Dimensions are 8.6 cm x 9.6 cm x 23.9 cm — the longest dimension is the depth behind the mounting surface, so check the clearance before you drill.","metaTitle":"ABB 2TLA050202R0332 LineStrong2 Pull Wire Emergency Stop Swi","metaDescription":"ABB LineStrong2 2TLA050202R0332 pull wire emergency stop switch. IP67 enclosure, 80 m wire span, IEC/EN60947-5-1 contacts. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Safety Relays"],"specifications":{"Weight":"0.9 Kg","Material":"Die cast painted yellow","Wire span":"Up to 80 m","Product No.":"2TLA050202R0332","Contact type":"IEC/EN60947-5-1 double break Typ Zb","Manufacturer":"ABB","Product Type":"LineStrong2 Pull Wire Emergency Stop Switch","Mounting bolts":"4 x M5","Conduit entries":"3 x M20 x 1.5","Shipping Weight":"2.5 Kg","lifecycle_stage":"current","Contact material":"Silver","Dimensions (LxWxH)":"8.6cm x 9.6cm x 23.9cm","Estimated Lead Time":"4 - 6 weeks.","Enclosure classification":"IP67"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/12afb697d773e81392a5ef62e7b4b32b.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/2TLA050202R0332/alternatives.json"},"ai":{"faq":[{"question":"What is the wire span on this pull-wire switch?","answer":"The wire span reaches up to 80 m, meaning one switch covers a long straight section without needing a second pull unit."},{"question":"What enclosure rating does the 2TLA050202R0332 carry?","answer":"IP67 — the die-cast painted yellow housing and contacts hold up to washdown, dust, and outdoor exposure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/2TLA050202R0332","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/2TLA050202R0332 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}