{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"30416","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"30416","canonicalUrl":"https://aoctrl.com/schneider/30416","factsUrl":"https://aoctrl.com/api/mcp/products/30416","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker Compact NS160DC - 160 A - 3 poles - without trip unit","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"161 mm","Standards":"IEC 60947-2","Control type":"Toggle","Network type":"DC","Mounting mode":"Fixed","Protection type":"Without protection","lifecycle_stage":"unknown","Connection pitch":"35 mm","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60947","Range of product":"Compact NS100...630","Breaking capacity":"100 kA Icu at 250 V DC 1P conforming to IEC 60947-2 100 kA Icu at 48/125 V DC 1P conforming to IEC 60947-2 100 kA Icu at 500 V DC 2P conforming to IEC 60947-2 100 kA Icu at 750 V DC 3P conforming to IEC 60947-2","Device short name":"Compact NS160DC","Poles description":"3P","Upside connection":"Front","[In] rated current":"160 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Compact NS160DC","Utilisation category":"Category A","Electrical durability":"10000 cycles 250 V DC In/2 conforming to IEC 60947-2 10000 cycles 500 V DC In/2 conforming to IEC 60947-2 10000 cycles 750 V DC In/2 conforming to IEC 60947-2 5000 cycles 250 V DC In conforming to IEC 60947-2 5000 cycles 500 V DC In conforming to IEC 60947-2 5000 cycles 750 V DC In conforming to IEC 60947-2","Maximum breaking time":"10 ms","Mechanical durability":"10000 cycles conforming to IEC 60947-2","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 conforming to IEC 60529","Product or component type":"Basic frame","Suitability for isolation":"Yes conforming to IEC 60947-2","[Ui] rated insulation voltage":"800 V DC conforming to IEC 60947-2","[Ue] rated operational voltage":"750 V DC conforming to IEC 60947-2","Ambient air temperature for storage":"-50...85 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"100 kA at 250 V DC conforming to IEC 60947-2 (1P) 100 kA at 48/125 V DC conforming to IEC 60947-2 (1P) 100 kA at 500 V DC conforming to IEC 60947-2 (2P) 100 kA at 750 V DC conforming to IEC 60947-2 (3P)","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/59828745a5e0ab29a0659f2ad14b4a72.pdf","sourceUrl":"https://www.se.com/nl/en/product/30416/circuit-breaker-compact-ns160dc-160-a-3-poles-without-trip-unit/","alternativesUrl":"https://aoctrl.com/api/mcp/products/30416/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/30416","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/30416 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}