{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"32934","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"32934","canonicalUrl":"https://aoctrl.com/schneider/32934","factsUrl":"https://aoctrl.com/api/mcp/products/32934","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker Vigicompact NS630N - STR23SE - 630A - 4 poles 4d - 300..30000mA","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"110 mm","Width":"185 mm","Height":"355 mm","Standards":"IEC 60947-2","Control type":"Toggle","Display type":"LED","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"STR23SE","Protection type":"Instantaneous short-circuit protection Protection of the fourth pole Overload protection (long time) Short time short-circuit protection Earth-leakage protection","lifecycle_stage":"unknown","Connection pitch":"45 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Neutral position":"Left","Pollution degree":"3 conforming to IEC 60947","Range of product":"Compact NS100...630","Trip unit rating":"630 A","Breaking capacity":"85 kA at 240 V AC 50/60 Hz conforming to NEMA AB1 HIC 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 480 V AC 50/60 Hz conforming to NEMA AB1 HIC 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Compact NS630N","Network frequency":"50/60 Hz","Poles description":"4P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"500 A at 65 °C 630 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Vigicompact NS630N","Trip unit technology":"Electronic","Utilisation category":"Category A","Electrical durability":"4000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2 8000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2","Mechanical durability":"15000 cycles","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to EN 50102","IP degree of protection":"IP40 conforming to IEC 60529","Earth-leakage protection":"With","Circuit breaker CT rating":"630 A","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Neutral protection setting":"No protection 1 x Ir 0.5 x Ir","Protected poles description":"3t 4t 3t + N/2","[Ui] rated insulation voltage":"750 V AC 50/60 Hz conforming to IEC 60947-2","Earth-leakage protection class":"Class A","[Ue] rated operational voltage":"440 V AC 50/60 Hz conforming to IEC 60947-2","Long time delay adjustment type":"Fixed","Earth-leakage add-on module name":"MB","Short-time delay adjustment type":"Fixed","Long time pick-up adjustment range":"0.4...1 x In","Ambient air temperature for storage":"-50...85 °C","Long time pick-up adjustment type Ir":"Adjustable 48 settings","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2","[Tr] Long-Time Delay Adjustment Range":"90...180 s 1.5 x Ir 3.2...5 s 7.2 x Ir 5...7.5 s 6 x Ir","Instantaneous pick-up adjustment range":"11 x In","Short-time pick-up adjustment type Isd":"Adjustable 8 settings","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","[Tsd] Short-Time Delay Adjustment Range":"0.04...0.06 s","Instantaneous pick-up adjustment type Ii":"Fixed","[Isd] short-time pick-up adjustment range":"2...10 x Ir","Residual earth-leakage sensitity adjustment type":"Adjustable","Residual earth-leakage time delay adjustment type":"Adjustable","[IΔn] residual earth-leakage sensitive adjustment":"30 A 10 A 0.3 A 1 A 3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ee760f76872615ace02927f85544c5d0.pdf","sourceUrl":"https://www.se.com/vn/en/product/32934/circuit-breaker-vigicompact-ns630n-str23se-630a-4-poles-4d-300-30000ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/32934/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/32934","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/32934 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}