{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"37653","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"37653","canonicalUrl":"https://aoctrl.com/schneider/37653","factsUrl":"https://aoctrl.com/api/mcp/products/37653","rawCanonicalId":null},"summary":{"shortDescription":"circuit breaker Compact NSF150N - TMD - 30 A - 3 poles 3d","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Molded Case Circuit Breakers (MCCB)"],"specifications":{"Depth":"86 mm","Width":"105 mm","Height":"161 mm","Standards":"IEC 60947-2","Control type":"Toggle","Network type":"AC","Mounting mode":"Fixed","Trip unit name":"TM-D","Protection type":"Overload protection (thermal) Short-circuit protection (magnetic)","lifecycle_stage":"unknown","Connection pitch":"35 mm","Local signalling":"Positive contact indication","Mounting support":"Backplate","Pollution degree":"3 conforming to IEC 60529","Range of product":"NSF100...250","Trip unit rating":"27 A at 60 °C 30 A at 40 °C 25.6 A at 70 °C 28.5 A at 50 °C","Breaking capacity":"22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 250 V DC 1P conforming to IEC 60947-2 50 kA Icu at 500 V DC 2P conforming to IEC 60947-2 8 kA Icu at 600/690 V AC 50/60 Hz conforming to IEC 60947-2","Device short name":"Compact NSF150N","Network frequency":"50/60 Hz","Poles description":"3P","Upside connection":"Front","Device application":"Distribution","[In] rated current":"150 A at 40 °C","Downside connection":"Front","Circuit breaker name":"Compact NSF150N","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Breaking capacity code":"N","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP40 conforming to IEC 60529","Product or component type":"Circuit breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Protected poles description":"3t","[Ui] rated insulation voltage":"750 V AC 50/60 Hz conforming to IEC 60947-2","[Ue] rated operational voltage":"500 V DC conforming to IEC 60947-2","Long time pick-up adjustment range":"0.8...1 x In","Long time pick-up adjustment type Ir":"Adjustable","Ambient air temperature for operation":"20...70 °C","[Ics] rated service breaking capacity":"22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 250 V DC conforming to IEC 60947-2 50 kA at 500 V DC conforming to IEC 60947-2 8 kA at 600/690 V AC 50/60 Hz conforming to IEC 60947-2","Instantaneous pick-up adjustment range":"400 A","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947-2","Instantaneous pick-up adjustment type Ii":"Fixed"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7a67992a0214c4b6f40fc17eab04c485.pdf","sourceUrl":"https://www.se.com/vn/en/product/37653/circuit-breaker-compact-nsf150n-tmd-30-a-3-poles-3d/","alternativesUrl":"https://aoctrl.com/api/mcp/products/37653/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/37653","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/37653 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}