{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00038113-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00038113-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00038113-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00038113-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-01 wall-mounted single drive, frame size R2, 7.5 kW / 14 A normal use, 380-500 VAC, IP21, IE2.","salesMarkdown":"The 3ABD00038113-D: Frame size R2 keeps the footprint compact for wall mounting, and the IE2 efficiency level meets the baseline for fixed-speed and variable-torque applications. The normal-use rating (7.5 kW, 14 A) covers constant-torque loads like conveyors and positive-displacement pumps. The heavy-duty rating (5.5 kW, 11 A) applies to higher-torque demands such as crushers, extruders, or vertical lifts where overload capacity is critical. A light-overload rating of 7.5 kW at 13 A sits between the two, giving flexibility for applications with moderate peak demands.","metaTitle":"ABB 3ABD00038113-D ACS880-01 Drive, 7.5 kW, 14 A, Frame R2","metaDescription":"ABB ACS880-01 wall-mounted drive, 7.5 kW normal-use output at 14 A, frame size R2, 380-500 VAC input, IP21, IE2. Active lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"7.5 kW","Output Current, Normal Use (In)":"14 A","Output Power, Heavy-Duty Use (PhD)":"5.5 kW","Output Current, Heavy-Duty Use (IhD)":"11 A","Output Power, Light-Overload Use (PlD)":"7.5 kW","Output Current, Light-Overload Use (IlD)":"13 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00038113-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00038113-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R2, which determines the physical mounting footprint and the compatible options kit."},{"question":"What are the normal-use and heavy-duty output ratings?","answer":"Normal use: 7.5 kW at 14 A. Heavy duty: 5.5 kW at 11 A. Light overload: 7.5 kW at 13 A."},{"question":"What input voltage and frequency does it accept?","answer":"Three-phase 380-500 VAC at 47.5-63 Hz."},{"question":"What is the enclosure protection rating?","answer":"IP21 with NEMA Type 1, suitable for indoor installations where drips and falling dirt are a concern."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00038113-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00038113-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}