{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00038129-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00038129-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00038129-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00038129-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-01 wall-mounted single drive, 380-500 V 3-phase, 37 kW / 65 A normal use, 30 kW / 52 A heavy-duty, IP21, NEMA 1, IE2, R5 frame.","salesMarkdown":"This 3ABD00038129-D is an ABB ACS880-01 wall-mounted single drive in R5 frame size, rated 37 kW normal use at 65 A output on 380-500 V three-phase supply. The light-overload rating sits at 37 kW / 62 A, so for variable-torque (pump/fan) applications the normal-use figure governs. Frequency range 47.5 to 63 Hz covers both 50 and 60 Hz grids without derating. IP21 with NEMA Type 1 enclosure — suitable for clean indoor environments where dripping water or incidental contact is the concern, not hose-down or dust. Wall-mounted, so plan for adequate clearance around the R5 frame for airflow and cable entry. The WEEE category 4 classification (large equipment >50 cm) applies for end-of-life disposal tracking in EU markets.","metaTitle":"ABB 3ABD00038129-D ACS880-01 Drive, 37 kW, 65 A, IP21","metaDescription":"ABB ACS880-01 wall-mounted drive, 37 kW normal use (65 A), 30 kW heavy-duty (52 A). 380-500 V, 3-phase, IP21, NEMA 1, IE2, R5 frame. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R5","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"37 kW","Output Current, Normal Use (In)":"65 A","Output Power, Heavy-Duty Use (PhD)":"30 kW","Output Current, Heavy-Duty Use (IhD)":"52 A","Output Power, Light-Overload Use (PlD)":"37 kW","Output Current, Light-Overload Use (IlD)":"62 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00038129-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00038129-D/alternatives.json"},"ai":{"faq":[{"question":"What are the key power ratings for this drive?","answer":"Normal use: 37 kW / 65 A. Heavy-duty: 30 kW / 52 A. Light-overload: 37 kW / 62 A. Input voltage: 380-500 V three-phase at 47.5-63 Hz."},{"question":"What is the frame size and enclosure type?","answer":"R5 frame size, IP21 / NEMA Type 1 enclosure, wall-mounted. Suitable for indoor, clean environments."},{"question":"What efficiency class does this drive meet?","answer":"IE2 efficiency level is listed on the rating plate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00038129-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00038129-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}