{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00038177-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00038177-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00038177-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00038177-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-01 wall-mounted drive, 3ABD00038177-D, 4 kW / 7.6 A normal use, 3-phase 380-500 V, IP21, frame size R1.","salesMarkdown":"The ABB 3ABD00038177-D is a wall-mounted single drive rated for 4 kW normal-use output at 7.6 A, with a heavy-duty rating of 3 kW at 5.2 A. It runs on three-phase 380–500 V input, 47.5–63 Hz, and carries IE2 efficiency. Frame size R1, IP21, NEMA 1 enclosure. The normal-use current of 7.6 A (4 kW) is the figure to match against your motor nameplate for continuous duty. Heavy-duty use drops to 5.2 A (3 kW) — that's the rating for constant-torque loads like conveyors or extruders where the drive sees sustained overload. Light-overload use sits at 7.2 A (4 kW), a middle band for applications with occasional peak demand. IP21 with NEMA 1 enclosure means it's suited for indoor, dry locations — no washdown or dust. Wall-mounted, frame R1. The gland plate area is sized for the input and motor cable entries typical of a 4 kW drive; leave clearance for bending radius on the output cables.","metaTitle":"ABB 3ABD00038177-D ACS880-01 Drive, 4 kW / 7.6 A, IP21","metaDescription":"ABB ACS880-01 wall-mounted drive, 4 kW normal-use output at 7.6 A, 3-phase 380-500 V input. Frame size R1, IP21, IE2. Active lifecycle, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"7.6 A","Output Power, Heavy-Duty Use (PhD)":"3 kW","Output Current, Heavy-Duty Use (IhD)":"5.2 A","Output Power, Light-Overload Use (PlD)":"4 kW","Output Current, Light-Overload Use (IlD)":"7.2 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00038177-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00038177-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R1, which is the smallest mechanical format in the ACS880-01 wall-mounted range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00038177-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00038177-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}