{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00039236-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00039236-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00039236-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00039236-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-01, LV AC industrial wall-mounted single drive, 30 kW normal use, 35 A output current, 525-690 V 3-phase input, frame size R5, IP21, IE2.","salesMarkdown":"The ABB 3ABD00039236-D is an ACS880-01 wall-mounted drive rated for 30 kW normal use at 35 A output current on a 525-690 V three-phase supply. That 35 A figure is the continuous rating you size your motor and cabling for under normal duty — it carries a 3-phase induction motor up to that current without derating, provided the ambient stays within the drive's limits. Frame size R5 tells you the physical envelope — this drive needs cabinet space matching the R5 footprint, so verify your enclosure depth and mounting rail spacing before committing the BOM line. The 525-690 V input range covers 690 V nominal grids common in European industrial plants, but also works on 600 V Canadian systems and 575 V North American installations — check your line voltage falls within that band, not just the nominal. IP21 with NEMA Type 1 means it's built for indoor, clean environments; no washdown rating here, so keep it out of wet or dusty areas unless you add a separate enclosure. ## Integration notes Wall-mounted design with NEMA Type 1 enclosure — mount it directly to a backplate or inside a panel, not on a DIN rail. IE2 efficiency level meets the base standard for motor drives; if your site requires IE3 or IE4 for energy compliance, factor that into the drive selection — this unit won't carry premium efficiency credits.","metaTitle":"ABB 3ABD00039236-D ACS880-01 Drive, 30 kW, 35 A, Frame R5","metaDescription":"ABB ACS880-01 wall-mounted drive, 30 kW normal use, 35 A output, 525-690 V input, IP21, IE2, frame R5. Active production. Source to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 600V"],"specifications":{"Frame Size":"R5","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"525 ... 690 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"30 kW","Output Current, Normal Use (In)":"35 A","Output Power, Heavy-Duty Use (PhD)":"22 kW","Output Current, Heavy-Duty Use (IhD)":"26 A","Output Power, Light-Overload Use (PlD)":"30 kW","Output Current, Light-Overload Use (IlD)":"33 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00039236-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00039236-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size and what does it mean for installation?","answer":"Frame size R5 defines the physical dimensions and mounting footprint. This is a wall-mounted drive (NEMA Type 1), so plan for backplate or panel mounting — not DIN rail — and verify cabinet depth for the R5 envelope before ordering."},{"question":"What are the key ratings for motor sizing?","answer":"Normal-use output is 30 kW at 35 A; heavy-duty use is 22 kW at 26 A. The 35 A normal-use figure is the continuous rating for sizing motor and cable. Use the 26 A heavy-duty rating for constant-torque loads like conveyors."},{"question":"What input voltage and frequency does this drive accept?","answer":"Input voltage range is 525-690 V three-phase, covering 690 V European grids, 600 V Canadian, and 575 V North American systems. Frequency range is 47.5-63 Hz, so it handles both 50 Hz and 60 Hz supplies without reconfiguration."},{"question":"What is the enclosure rating and where can it be installed?","answer":"IP21 with NEMA Type 1 enclosure — suitable for indoor, clean, dry environments. Not rated for washdown or outdoor use; install in a cabinet or controlled area to keep out dust and moisture."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00039236-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00039236-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}