{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00045723-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00045723-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00045723-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00045723-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ580-01-062A-4+B056, LV AC wall-mounted drive, 30 kW / 62 A normal use, 22 kW heavy duty, IP55, NEMA 12, Frame R4.","salesMarkdown":"The 3ABD00045723-D is an ABB LV AC wall-mounted drive, sized for a 30 kW motor on 380-500 V three-phase supply. Normal-use output is 62 A; heavy-duty use drops to 22 kW and 44.6 A for constant-torque loads. Light-overload use holds 30 kW at 58 A. IP55 and NEMA Type 12 enclosure allows wall mounting in treatment areas. The 62 A normal-use current is the number to match against your motor FLA for variable-torque applications (fans, centrifugal pumps). For constant-torque loads, use the 44.6 A heavy-duty figure — that's the rating that governs thermal capacity under full torque at low speed. The 380-500 V input range covers 400 V and 480 V nominal grids; the 47.5-63 Hz frequency tolerance handles 50 Hz and 60 Hz supplies without derating. IE2 efficiency is baseline for this power class; if your site targets IE3 or IE4, the drive itself doesn't impose a penalty — the motor efficiency is what matters.","metaTitle":"3ABD00045723-D ABB ACQ580-01-062A-4+B056 30 kW, 62 A, IP55,","metaDescription":"ABB ACQ580-01-062A-4+B056 (3ABD00045723-D) LV AC wall-mounted drive, 30 kW / 62 A normal use, 22 kW / 44.6 A heavy duty, IP55, NEMA 12, IE2, 380-500 V, 47.5-63 Hz. Active productio","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R4","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type12","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP55","Output Power, Normal Use (Pn)":"30 kW","Output Current, Normal Use (In)":"62 A","Output Power, Heavy-Duty Use (PhD)":"22 kW","Output Current, Heavy-Duty Use (IhD)":"44.6 A","Output Power, Light-Overload Use (PlD)":"30 kW","Output Current, Light-Overload Use (IlD)":"58 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00045723-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00045723-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R4. This determines physical mounting dimensions and the gland plate layout for cable entry."},{"question":"What enclosure protection does it have?","answer":"IP55 and NEMA Type 12. Suitable for washdown areas and dusty environments; no additional cabinet required for most water/wastewater installations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00045723-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00045723-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}