{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00045773-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00045773-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00045773-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00045773-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB, ACS580-04 series, LV AC general purpose drive module, 3ABD00045773-D, 250 kW normal-use, 505 A output, 380-480 V 3-phase input, frame R10, IP00.","salesMarkdown":"## Drive module for 250 kW motor loads The ABB 3ABD00045773-D is an active-production LV AC general purpose drive module rated for 250 kW normal-use output at 505 A and 380-480 V three-phase input. Frame size R10, IP00 open type — this is a chassis module intended for panel integration, not standalone floor mounting. Three duty ratings are listed: normal-use (Pn 250 kW, In 505 A), heavy-duty (PhD 200 kW, IhD 361 A), and light-overload (PlD 250 kW, IlD 485 A). The heavy-duty figure governs continuous operation on a constant-torque load like a conveyor or extruder; the normal-use rating applies to variable-torque loads such as centrifugal pumps and fans. The light-overload current sits between the two — useful for applications with occasional peak demand but not sustained high torque. ## Physical and electrical fit Frame R10 defines the mechanical footprint and bus-bar layout — verify panel cutout and mounting rail compatibility with the installation manual. Input accepts 380-480 V at 47.5-63 Hz, three-phase. IP00 means no built-in protection against dust or water ingress; the enclosure must provide the required IP rating. Efficiency class IE2 is standard for this generation.","metaTitle":"ABB 3ABD00045773-D ACS580-04 Drive Module, 250 kW, 505 A","metaDescription":"ABB ACS580-04 drive module, 250 kW normal-use, 505 A output, 380-480 V 3-phase input. Active production, frame R10, IP00 open type. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R10","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP00","Output Power, Normal Use (Pn)":"250 kW","Output Current, Normal Use (In)":"505 A","Output Power, Heavy-Duty Use (PhD)":"200 kW","Output Current, Heavy-Duty Use (IhD)":"361 A","Output Power, Light-Overload Use (PlD)":"250 kW","Output Current, Light-Overload Use (IlD)":"485 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00045773-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00045773-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive module?","answer":"Frame size R10, which governs the physical dimensions and bus-bar layout for panel integration."},{"question":"What input voltage and frequency does it accept?","answer":"380-480 V three-phase, 47.5-63 Hz."},{"question":"What are the normal-use and heavy-duty power ratings?","answer":"Normal-use: 250 kW, 505 A. Heavy-duty: 200 kW, 361 A. Light-overload: 250 kW, 485 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00045773-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00045773-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}