{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00046128","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00046128","canonicalUrl":"https://aoctrl.com/abb/3ABD00046128","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00046128","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01, 3ABD00046128, 5.5 kW LV AC general purpose wall-mounted drive, 380-500 V 3-phase, 12.6 A normal use output, Frame R1, IP21.","salesMarkdown":"The 3ABD00046128: Normal-use rating (Pn 5.5 kW, In 12.6 A) is the headline spec, but the heavy-duty curve matters if you're driving a pump or fan with a constant-torque profile. Heavy-duty use is rated at 4 kW and 9.4 A — that's the figure to size against for a positive-displacement pump or a conveyor. Light-overload use (5.5 kW, 12 A) mirrors the normal-use power but pulls slightly less current, which suggests a lower crest factor in the load profile. If your motor plate says 5.5 kW but your application cycles hard, check the heavy-duty column first. Wall-mounted, frame R1. If this drive is going into a panel that sees hose spray or high humidity, you'd need a higher IP rating or a separate enclosure. The NEMA Type 1 rating confirms indoor use only.","metaTitle":"ABB 3ABD00046128 ACS580-01 Drive, 5.5 kW, 12.6 A, Frame R1","metaDescription":"ABB ACS580-01 general purpose drive, 5.5 kW output at 12.6 A normal use, 380-500 V 3-phase input. Frame size R1, IP21, wall-mounted. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"5.5 kW","Output Current, Normal Use (In)":"12.6 A","Output Power, Heavy-Duty Use (PhD)":"4 kW","Output Current, Heavy-Duty Use (IhD)":"9.4 A","Output Power, Light-Overload Use (PlD)":"5.5 kW","Output Current, Light-Overload Use (IlD)":"12 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00046128","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00046128/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R1."},{"question":"What is the input voltage and frequency range?","answer":"Input voltage is 380-500 V three-phase, frequency range 47.5-63 Hz."},{"question":"What are the heavy-duty output ratings?","answer":"Heavy-duty use: 4 kW output at 9.4 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00046128","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00046128 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}