{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00046367","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00046367","canonicalUrl":"https://aoctrl.com/abb/3ABD00046367","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00046367","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH531-01-145A-4, LV AC wall-mounted drive, 75 kW, 145 A, IP20, frame R6.","salesMarkdown":"The ABB 3ABD00046367 is an ACH531-01-145A-4 LV AC wall-mounted drive rated for 75 kW normal-use output at 145 A, in frame size R6. It operates on a 380 to 480 V three-phase supply at 47.5 to 63 Hz, and is listed as active in production. The 75 kW normal-use power (Pn) and 145 A output current (In) define the continuous motor load this drive can handle under IEC conditions. Light-overload duty is rated at the same 75 kW but with a slightly lower 138 A current (IlD), which means the drive is sized for constant-torque applications where peak demand stays within that envelope. Standby loss is 36 W, a figure to account for in panel thermal calculations when the drive is powered but not driving a load. The IP20 enclosure suits indoor cabinet mounting where no washdown or dust ingress protection is required. Efficiency is rated IE2, which sets the minimum energy performance level for this drive class under IEC 61800-9-2. The maximum ambient temperature is 40 °C, so derating applies above that threshold.","metaTitle":"ABB 3ABD00046367 ACH531-01-145A-4, 75 kW, 145 A","metaDescription":"ABB ACH531-01-145A-4 LV AC wall-mounted drive, 75 kW, 145 A output, IP20, frame R6. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R6","Standby Loss":"36 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"Product Not in WEEE Scope","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"100.0 kV·A","Output Power, Normal Use (Pn)":"75 kW","Output Current, Normal Use (In)":"145 A","Output Power, Light-Overload Use (PlD)":"75 kW","Output Current, Light-Overload Use (IlD)":"138 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00046367","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00046367/alternatives.json"},"ai":{"faq":[{"question":"What is 3ABD00046367's listed frame size?","answer":"Frame size R6."},{"question":"What is the standby loss of this drive?","answer":"36 W."},{"question":"What are the key output ratings?","answer":"Normal-use output is 75 kW at 145 A; light-overload output is 75 kW at 138 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00046367","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00046367 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}