{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00046368","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00046368","canonicalUrl":"https://aoctrl.com/abb/3ABD00046368","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00046368","rawCanonicalId":null},"summary":{"shortDescription":"ABB, ACH531-01 series, LV AC wall-mounted drive for HVAC, 3ABD00046368, 90 kW, 169 A, IP20, Frame R7.","salesMarkdown":"The ABB 3ABD00046368 is a wall-mounted LV AC drive for HVAC duty. Rated 90 kW normal use at 169 A output current, with light-overload capability at the same 90 kW (161 A). Input accepts 380–480 V three-phase, 47.5–63 Hz. Frame size R7, IP20 enclosure, open type per NEMA. Standby loss sits at 36 W. The 90 kW normal-use rating (Pn) matches the motor nameplate for continuous fan or pump loads. Light-overload (PlD) is also 90 kW, so the drive is sized for constant-torque HVAC profiles without extra headroom. The 169 A normal-use current (In) is the figure to check against the motor FLA; the 161 A light-overload current (IlD) applies when the drive runs below 40 °C ambient. IE2 efficiency keeps losses predictable for energy calculations.","metaTitle":"ABB 3ABD00046368 ACH531-01 HVAC Drive, 90 kW, 169 A","metaDescription":"ABB ACH531-01 LV AC wall-mounted drive for HVAC, 380-480 V 3-phase, 90 kW normal use, 169 A output, IP20, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R7","Standby Loss":"36 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"Product Not in WEEE Scope","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"117.0 kV·A","Output Power, Normal Use (Pn)":"90 kW","Output Current, Normal Use (In)":"169 A","Output Power, Light-Overload Use (PlD)":"90 kW","Output Current, Light-Overload Use (IlD)":"161 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00046368","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00046368/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of 3ABD00046368?","answer":"Frame size R7."},{"question":"What is the standby loss of this drive?","answer":"Standby loss is 36 W."},{"question":"What compliance documentation is available for this drive?","answer":"The drive carries an IP20 degree of protection and is classified as Product Not in WEEE Scope. For detailed compliance documents (RoHS, REACH, UL, IEC), request them with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00046368","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00046368 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}