{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00046390","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00046390","canonicalUrl":"https://aoctrl.com/abb/3ABD00046390","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00046390","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACQ531-01-145A-4, 75 kW drive, 145 A output, 380-480 V 3-phase, Frame R6, IP20, active.","salesMarkdown":"The ABB 3ABD00046390 is an ACQ531-01-145A-4 drive rated for 75 kW normal use at 145 A output, fed from a 380-480 V 3-phase supply. Frame R6, IP20 open-type enclosure. Standby loss sits at 36 W — a figure to factor into panel cooling if the drive spends significant time idle. Efficiency class IE2, which is the baseline for this generation; no premium-efficiency label here, so the thermal design assumes that loss level. Light-overload duty (PlD) is also 75 kW with 138 A. Frame R6 is a bolted-mount chassis, not a DIN-rail clip. IP20 means it's intended for a clean, dry enclosure — no washdown or dust tolerance. The open-type NEMA rating confirms it needs a surrounding cabinet for personnel protection. Panel layout should account for the 36 W standby heat dissipation even when the motor is stopped.","metaTitle":"ABB 3ABD00046390 ACQ531-01-145A-4 Drive, 75 kW, 145 A, Frame","metaDescription":"ABB ACQ531-01-145A-4 drive, 75 kW normal use, 145 A output, 380-480 V 3-phase input, Frame R6, IP20, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R6","Standby Loss":"36 W","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Temperature Rating":"Maximum 40 °C","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Apparent Power Output":"100.0 kV·A","Output Power, Normal Use (Pn)":"75 kW","Output Current, Normal Use (In)":"145 A","Output Power, Light-Overload Use (PlD)":"75 kW","Output Current, Light-Overload Use (IlD)":"138 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00046390","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00046390/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of 3ABD00046390?","answer":"Frame R6 — a bolted-mount chassis size, not a DIN-rail format."},{"question":"What is the standby loss of this drive?","answer":"36 W. This is the power consumed when the drive is enabled but not delivering output to the motor."},{"question":"What are the key output ratings?","answer":"75 kW normal use, 145 A output current at 380-480 V 3-phase input. Light-overload rating is also 75 kW at 138 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00046390","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00046390 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}