{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00046798-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00046798-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00046798-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00046798-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01, 3ABD00046798-D, LV AC general purpose wall-mounted drive, 110 kW / 206 A normal use, 380-480 V 3-phase, Frame R7, IP20, NEMA Open Type, IE2.","salesMarkdown":"The ABB 3ABD00046798-D is a general-purpose wall-mounted drive rated for 110 kW normal-use output at 206 A on a 380-480 V 3-phase supply. Heavy-duty cycle drops to 90 kW and 169 A. Frame size R7 and wall-mount format mean this drive occupies a dedicated footprint on a backplate or structural wall — not a DIN rail. The NEMA Open Type enclosure (IP20) suits clean, dry indoor environments; plan for filtered airflow or a cabinet if the ambient carries dust or condensation. Frequency acceptance spans 47.5 to 63 Hz. IE2 efficiency level meets the base EU directive requirement for this power class.","metaTitle":"ABB 3ABD00046798-D ACS580-01 Drive, 110 kW, 206 A, Frame R7","metaDescription":"Active ABB ACS580-01 wall-mounted drive, 110 kW normal-use output, 206 A, 380-480 V 3-phase, IP20, NEMA Open Type, IE2. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R7","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"110 kW","Output Current, Normal Use (In)":"206 A","Output Power, Heavy-Duty Use (PhD)":"90 kW","Output Current, Heavy-Duty Use (IhD)":"169 A","Output Power, Light-Overload Use (PlD)":"110 kW","Output Current, Light-Overload Use (IlD)":"196 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00046798-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00046798-D/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"Normal-use output is 110 kW at 206 A; heavy-duty output is 90 kW at 169 A. Input is 380-480 V 3-phase, 47.5-63 Hz. Frame size R7, IP20, NEMA Open Type, IE2 efficiency."},{"question":"What is the frame size and mounting type?","answer":"Frame size R7, wall-mounted. It is not a DIN-rail unit; plan for a backplate or structural wall mount."},{"question":"What compliance documentation is available?","answer":"The drive carries an IE2 efficiency classification and is WEEE Category 4 (Large Equipment). Full RoHS, REACH, and UL/IEC declarations are part of the ABB documentation package; request them with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00046798-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00046798-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}