{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00046995-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00046995-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00046995-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00046995-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS880-01 LV AC drive, Frame R1, 5.5 kW / 11 A normal use, IP21, NEMA Type 1, 380-500 V 3-phase, IE2.","salesMarkdown":"The ABB 3ABD00046995-D is an active-production ACS880-01 wall-mounted single drive, Frame R1, rated 5.5 kW normal-use output at 11 A (380-500 V, 3-phase). Heavy-duty duty cycle drops to 4 kW / 7.6 A; light-overload holds at 5.5 kW / 10.4 A. IP21 with NEMA Type 1 enclosure keeps it clean for panel or machine-mount — no extra gland plate needed for dry indoor environments. Efficiency level IE2, frequency range 47.5-63 Hz.","metaTitle":"ABB 3ABD00046995-D ACS880-01 Drive, IP21, 5.5 kW, 11 A","metaDescription":"Active ABB ACS880-01 drive, 3ABD00046995-D, 5.5 kW normal use, 11 A output, IP21, NEMA 1, IE2. Frame R1, 380-500 V, 3-phase. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"Product Not in WEEE Scope","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"5.5 kW","Output Current, Normal Use (In)":"11 A","Output Power, Heavy-Duty Use (PhD)":"4 kW","Output Current, Heavy-Duty Use (IhD)":"7.6 A","Output Power, Light-Overload Use (PlD)":"5.5 kW","Output Current, Light-Overload Use (IlD)":"10.4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00046995-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00046995-D/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this drive?","answer":"Normal-use output: 5.5 kW at 11 A. Heavy-duty: 4 kW at 7.6 A. Light-overload: 5.5 kW at 10.4 A. Input voltage 380-500 V, 3-phase, 47.5-63 Hz. Frame R1, IP21, NEMA Type 1, IE2 efficiency."},{"question":"What is the frame size and mounting?","answer":"Frame R1, wall-mounted. IP21 with NEMA Type 1 enclosure suits dry indoor panel or machine-mount installations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00046995-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00046995-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}