{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00047425-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00047425-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00047425-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00047425-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACH580-01 wall-mounted HVAC drive, 4 kW / 9.4 A normal duty, 380–480 V 3-phase, IP21, NEMA 1, IE2, Frame R1.","salesMarkdown":"The 3ABD00047425-D: Three duty curves are listed: normal-use (Pn 4 kW, In 9.4 A), heavy-duty (PhD 3.0 kW, IhD 7.2 A), and light-overload (PlD 4.0 kW, IlD 8.9 A). The heavy-duty curve handles a motor that needs torque margin for short peaks, say a centrifuge or a conveyor start. Light-overload sits between them, useful when the duty cycle is intermittent but not severe. Pick the curve that matches your driven load's actual profile, not the highest number. IP21 and NEMA Type 1 enclosure suits indoor, clean-area installations — think a motor control center or a mechanical room. Wall-mounted, so plan for a vertical surface with clearance for airflow; the frame R1 footprint is compact enough for retrofit into existing panel space.","metaTitle":"ABB 3ABD00047425-D ACH580-01 HVAC Drive, 4 kW, 9.4 A, Frame","metaDescription":"ABB ACH580-01 wall-mounted HVAC drive, 4 kW / 9.4 A normal duty, 380–480 V 3-phase, IP21, NEMA 1, IE2. Active production, sourced to order. Frame R1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"9.4 A","Output Power, Heavy-Duty Use (PhD)":"3.0 kW","Output Current, Heavy-Duty Use (IhD)":"7.2 A","Output Power, Light-Overload Use (PlD)":"4.0 kW","Output Current, Light-Overload Use (IlD)":"8.9 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00047425-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00047425-D/alternatives.json"},"ai":{"faq":[{"question":"What input voltage and frequency does this drive accept?","answer":"Input voltage is 380–480 V three-phase, frequency range 47.5 to 63 Hz."},{"question":"What is the efficiency level?","answer":"Rated IE2. That meets the minimum efficiency standard for most HVAC applications in Europe and aligns with common energy regulations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00047425-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00047425-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}