{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00048306-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00048306-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00048306-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00048306-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01-09A5-4+P974, LV AC general-purpose wall-mounted drive, 4 kW / 9.4 A, 380-500 V 3-phase, Frame R1, IP21, IE2.","salesMarkdown":"## Sizing against the load The 3ABD00048306-D: The normal-use (light-overload) rating at 4 kW / 9.4 A covers pumps, fans, and conveyors that don't need sustained peak torque. The heavy-duty rating drops to 3 kW / 7.2 A — that's the number to size against for constant-torque loads like extruders or positive-displacement pumps. If your motor plate says 4 kW and the application is a crusher, you'll want to step up a frame. Wall-mounted, Frame R1, IP21. That means it's fine for a dry, clean control room or machine cabinet — no dripping water, no conductive dust. The NEMA 1 enclosure is essentially a ventilated indoor box; if your plant floor sees coolant mist or flour dust, you'll need to either relocate it or add a separate enclosure.","metaTitle":"3ABD00048306-D ABB ACS580-01-09A5-4+P974 4 kW Drive, IP21, I","metaDescription":"Active-production ABB ACS580 drive, 4 kW normal-use / 3 kW heavy-duty, 9.4 A, 380-500 V 3-phase, IP21, IE2, Frame R1. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"4 kW","Output Current, Normal Use (In)":"9.4 A","Output Power, Heavy-Duty Use (PhD)":"3 kW","Output Current, Heavy-Duty Use (IhD)":"7.2 A","Output Power, Light-Overload Use (PlD)":"4 kW","Output Current, Light-Overload Use (IlD)":"8.9 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00048306-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00048306-D/alternatives.json"},"ai":{"faq":[{"question":"What are the key output ratings for 3ABD00048306-D?","answer":"Normal-use output is 4 kW at 9.4 A; heavy-duty output is 3 kW at 7.2 A. Light-overload rating is 4 kW at 8.9 A."},{"question":"What is the frame size and mounting style?","answer":"Frame size is R1, wall-mounted. The enclosure is IP21 / NEMA 1 for indoor use."},{"question":"What input voltage and frequency does it accept?","answer":"Three-phase 380-500 V, 47.5-63 Hz."},{"question":"How do I source this drive?","answer":"We source it to order against an RFQ. It's active-production, so lead time is standard for the ACS580 line."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00048306-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00048306-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}