{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00048506-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00048506-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00048506-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00048506-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 general-purpose wall-mounted drive, 3ABD00048506-D, 11 kW / 25 A normal use, 7.5 kW / 17 A heavy-duty, 380–480 V 3-phase, Frame R2, IP20, IE2.","salesMarkdown":"The 3ABD00048506-D: Efficiency is IE2, meeting the baseline standard for motor-drive applications. ## Normal-use vs heavy-duty ratings — which one fits your load The drive carries two current ratings: 25 A for normal use (11 kW) and 17 A for heavy-duty use (7.5 kW). For a constant-torque load like a conveyor running at full speed, the normal-use figure applies. For a pump or fan with variable torque, the heavy-duty rating gives headroom for short-term overloads. The light-overload rating (23.8 A / 11 kW) sits between them — use it when the duty cycle is moderate but not continuous full load.","metaTitle":"ABB 3ABD00048506-D ACS580 drive, 11 kW, 25 A, Frame R2","metaDescription":"ABB ACS580 general-purpose wall-mounted drive, 11 kW normal use (25 A), 7.5 kW heavy-duty (17 A). Active lifecycle, IE2 efficiency, IP20, 380–480 V 3-phase. Frame R2. Sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R2","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"11 kW","Output Current, Normal Use (In)":"25 A","Output Power, Heavy-Duty Use (PhD)":"7.5 kW","Output Current, Heavy-Duty Use (IhD)":"17.0 A","Output Power, Light-Overload Use (PlD)":"11.0 kW","Output Current, Light-Overload Use (IlD)":"23.8 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00048506-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00048506-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R2, which determines the physical mounting footprint and panel cutout dimensions."},{"question":"What are the key output ratings?","answer":"Normal use: 11 kW / 25 A. Heavy-duty use: 7.5 kW / 17 A. Light-overload use: 11 kW / 23.8 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00048506-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00048506-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}