{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00048692-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00048692-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00048692-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00048692-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS580-01 series, 3ABD00048692-D, LV AC general purpose wall-mounted drive, 380-480 V 3-phase, 37 kW / 73 A normal use, IP21, Type 1, Frame R4, IE2.","salesMarkdown":"## Duty ratings — normal vs heavy vs light overload The 3ABD00048692-D: Three operating curves are defined: normal use at 37 kW / 73 A, heavy-duty at 30 kW / 61 A, and light-overload at 37 kW / 68 A. The heavy-duty figure governs sizing for applications that demand sustained torque below base speed — match the 61 A IhD to the motor FLA if the load profile is constant-torque. For variable-torque loads (fans, centrifugal pumps) the normal-use 73 A gives headroom. Light-overload at 68 A splits the difference for cyclic duty. ## Mounting and enclosure details Wall-mounted, IP21 with NEMA Type 1 enclosure. The R4 frame includes the gland plate and cooling duct clearance typical for this class. No separate cabinet is required for the drive itself in a clean indoor environment, but the WEEE Category 4 classification (any external dimension >50 cm) means end-of-life disposal routing should be planned at commissioning. ## Efficiency class Rated IE2 efficiency. For projects where IE3 or IE4 is mandated by local energy regulations, confirm the motor-drive system efficiency target — the drive itself meets IE2, which is the baseline for many industrial installations.","metaTitle":"3ABD00048692-D ABB ACS580-01-073A-4+X1574 37 kW Drive, IP21,","metaDescription":"ABB ACS580-01 general purpose wall-mounted drive, 37 kW normal use, 73 A output, IP21, Type 1 enclosure, IE2 efficiency, active production. Frame R4.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R4","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"4. Large Equipment (Any External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Type1","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP21","Output Power, Normal Use (Pn)":"37 kW","Output Current, Normal Use (In)":"73 A","Output Power, Heavy-Duty Use (PhD)":"30.0 kW","Output Current, Heavy-Duty Use (IhD)":"61 A","Output Power, Light-Overload Use (PlD)":"37 kW","Output Current, Light-Overload Use (IlD)":"68 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00048692-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00048692-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R4."},{"question":"What are the heavy-duty output ratings?","answer":"30 kW / 61 A for heavy-duty (constant-torque) use."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00048692-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00048692-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}