{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00048770","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00048770","canonicalUrl":"https://aoctrl.com/abb/3ABD00048770","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00048770","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS530-01-12A6-4+0J404, 5.5 kW VFD, 12.6 A output, 380-500 VAC 3-phase input, IP20, Frame Size B1, IE2 efficiency.","salesMarkdown":"The ABB 3ABD00048770 is an ACS530-01-12A6-4+0J404 drive rated for 5.5 kW normal-use output at 12.6 A, fed from a 380-500 V three-phase supply. The IP20 enclosure suits clean indoor environments — plan for a filtered air intake if the cabinet sees dust or fibre. Efficiency lands at IE2, which is the baseline for this power class. No forced derating across the 47.5-63 Hz line frequency range, so it handles 50 Hz and 60 Hz mains without a firmware change. Wall-mounted unit, open-type NEMA enclosure. The B1 frame uses a standard gland plate for cable entry; leave clearance above and below for airflow and bending radius of the power cables. Light-overload rating matches the normal-use power at 5.5 kW, 12 A output current — no need to oversize for constant-torque loads up to that point.","metaTitle":"3ABD00048770 ABB ACS530-01-12A6-4+0J404 5.5 kW Drive, IP20,","metaDescription":"ABB ACS530-01-12A6-4+0J404 (3ABD00048770) 5.5 kW VFD, 12.6 A output, 380-500 V 3-phase input, IP20, Frame B1, IE2. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"B1","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"5.5 kW","Output Current, Normal Use (In)":"12.6 A","Output Power, Light-Overload Use (PlD)":"5.5 kW","Output Current, Light-Overload Use (IlD)":"12 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00048770","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00048770/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size B1. This determines the physical mounting footprint and gland plate layout."},{"question":"What compliance documentation is available for this drive?","answer":"The WEEE category is 5 (Small Equipment). The drive carries an IE2 efficiency classification. Specific RoHS, REACH, or UL certificates are not listed in the core spec record; request them with the RFQ if your compliance gate requires them."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00048770","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00048770 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}