{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00048776","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00048776","canonicalUrl":"https://aoctrl.com/abb/3ABD00048776","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00048776","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS530-01-062A-4+0J404, 30 kW / 62 A, 380-500 V 3-phase, IP20, Frame R4.","salesMarkdown":"The ABB 3ABD00048776 drive is rated for 30 kW normal-use output and 62 A continuous output current on a 380...500 V three-phase supply, with a frequency range of 47.5...63 Hz. Frame size R4, IP20 enclosure, open type (NEMA). Efficiency class IE2. ## Key Ratings & Fit The 62 A normal-use output current (In) matches the 30 kW rating for typical constant-torque motor loads. Light-overload duty (IlD) is 58 A, also at 30 kW — so the drive is sized for the same power whether the application is normal or light overload. Frame R4 is a compact wall-mount package; the IP20 rating means it is intended for clean, dry cabinet installation, not washdown or outdoor exposure.","metaTitle":"ABB 3ABD00048776 ACS530-01-062A-4 Drive, 30 kW, 62 A","metaDescription":"ABB ACS530-01-062A-4+0J404 drive, 30 kW / 62 A output, 380-500 V 3-phase input, IP20, frame R4. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Inverter / VFD"],"specifications":{"Frame Size":"R4","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Wall-mounted","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 500 V","Degree of Protection":"IP20","Output Power, Normal Use (Pn)":"30 kW","Output Current, Normal Use (In)":"62 A","Output Power, Light-Overload Use (PlD)":"30 kW","Output Current, Light-Overload Use (IlD)":"58 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00048776","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00048776/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R4."},{"question":"What input voltage and frequency does it accept?","answer":"Input voltage 380...500 V three-phase, frequency 47.5...63 Hz."},{"question":"What is the output power and current rating?","answer":"Normal-use output power 30 kW, output current 62 A. Light-overload ratings are 30 kW and 58 A."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00048776","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00048776 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}