{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"3ABD00050294-D","brand":"ABB","brandSlug":"abb","productSlug":"3ABD00050294-D","canonicalUrl":"https://aoctrl.com/abb/3ABD00050294-D","factsUrl":"https://aoctrl.com/api/mcp/products/3ABD00050294-D","rawCanonicalId":null},"summary":{"shortDescription":"ABB ACS530-04-880A-4+N7569+B051, 500 kW, 880 A, 380-480 V, 3-phase, IP00, Frame R11.","salesMarkdown":"The ABB 3ABD00050294-D is an ACS530-04-880A-4+N7569+B051 drive rated for 500 kW output power at 880 A normal-use current, with a light-overload rating of 865 A at the same power level. Input voltage range is 380 to 480 V three-phase, frequency range 47.5 to 63 Hz. Frame size R11, open-type NEMA enclosure, IP00 protection — this is a chassis-style drive intended for cabinet mounting, not standalone use. Both power ratings (Pn and PlD) are 500 kW, so the drive is not derated for light overload — the current margin is tight. The 380-480 V input covers 400 V and 480 V nominal grids; the 47.5-63 Hz frequency range handles 50 Hz and 60 Hz supplies without derating. Efficiency class IE2 is standard for this generation of ACS530 drives.","metaTitle":"ABB 3ABD00050294-D ACS530-04-880A-4+N7569+B051, 500 kW, 880","metaDescription":"ABB ACS530-04-880A-4+N7569+B051 drive, 500 kW output power, 880 A output current, 380-480 V input, active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["AC Drive (VFD) 480V"],"specifications":{"Frame Size":"R11","Frequency (f)":"47.5 ... 63 Hz","Mounting Type":"Module","WEEE Category":"5. Small Equipment (No External Dimension More Than 50 cm)","lifecycle_stage":"current","Efficiency Level":"IE2","Number of Phases":"3-phase","Enclosure Type NEMA":"Open Type","Input Voltage (Uin)":"380 ... 480 V","Degree of Protection":"IP00","Output Power, Normal Use (Pn)":"500 kW","Output Current, Normal Use (In)":"880 A","Output Power, Light-Overload Use (PlD)":"500 kW","Output Current, Light-Overload Use (IlD)":"865 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.abb.com/global/en/products/3abd00050294-d","alternativesUrl":"https://aoctrl.com/api/mcp/products/3ABD00050294-D/alternatives.json"},"ai":{"faq":[{"question":"What is the frame size of this drive?","answer":"Frame size R11."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/abb/3ABD00050294-D","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/abb/3ABD00050294-D when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}